template: kostal-plenticore-gen2
|
|
products:
|
|
- brand: Kostal
|
|
description:
|
|
de: Plenticore Hybrid
|
|
en: Plenticore Hybrid
|
|
capabilities: ["battery-control", "curtail"]
|
|
covers: ["kostal-plenticore-hw0200", "kostal-plenticore"]
|
|
caveats:
|
|
- description:
|
|
de: |
|
|
Nur ein System kann und darf auf den Wechselrichter zugreifen!
|
|
en: |
|
|
Only a single system may access the inverter!
|
|
link: https://github.com/evcc-io/evcc/wiki/Kostal-Plenticore
|
|
requirements:
|
|
description:
|
|
de: |
|
|
Anwendbar für verschiedene Wechselrichter Generationen (G1/G2/G3). Für die aktive Batteriesteuerung muss die Funktion externe Batteriesteuerung über Modbus mit dem Handwerkerzugang aktiviert sein.
|
|
en: |
|
|
Compatible with various inverter generations (G1/G2/G3). For active battery control, the feature external battery control via Modbus must be activated using installer access.
|
|
params:
|
|
- name: usage
|
|
choice: ["pv", "battery"]
|
|
- name: modbus
|
|
choice: ["tcpip"]
|
|
id: 71
|
|
port: 1502
|
|
- name: endianness
|
|
description:
|
|
de: Byte-Reihenfolge (Little/Big)
|
|
en: Endianness (Little/Big)
|
|
type: choice
|
|
choice: ["little", "big"]
|
|
default: little
|
|
advanced: true
|
|
- name: maxacpower
|
|
service: modbus/read?address=531&type=holding&encoding=uint16&{modbus}
|
|
- preset: battery-params
|
|
- name: capacity
|
|
service: modbus/read?address=1068&type=holding&encoding=float32s&scale=0.001&{modbus}
|
|
- name: minsoc
|
|
service: modbus/read?address=1042&type=holding&encoding=float32s&{modbus}
|
|
- name: maxsoc
|
|
service: modbus/read?address=1044&type=holding&encoding=float32s&{modbus}
|
|
- name: maxchargepower
|
|
service: modbus/read?address=1038&type=holding&encoding=float32s&resulttype=int&{modbus}
|
|
- name: maxdischargepower
|
|
service: modbus/read?address=1040&type=holding&encoding=float32s&resulttype=int&{modbus}
|
|
- name: maxchargerate
|
|
deprecated: true
|
|
- name: watchdog
|
|
default: 60s
|
|
render: |
|
|
{{- if eq .usage "pv" }}
|
|
type: custom
|
|
power:
|
|
source: calc
|
|
add: # The add plugin sums up all string values
|
|
- source: sunspec
|
|
{{- include "modbus" . | indent 4 }}
|
|
value: 160:1:DCW # string 1
|
|
- source: sunspec
|
|
{{- include "modbus" . | indent 4 }}
|
|
value: 160:2:DCW # string 2
|
|
- source: sunspec
|
|
{{- include "modbus" . | indent 4 }}
|
|
value: 160:3:DCW # string 3
|
|
energy:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
register:
|
|
address: 1056 # total DC PV energy (sum), Wh
|
|
type: holding
|
|
encoding: {{ if (eq .endianness "big") }}float32{{ else }}float32s{{ end }}
|
|
scale: 0.001 # Wh -> kWh
|
|
maxacpower: {{ .maxacpower }} # W
|
|
# feed-in curtailment via active power limit (SunSpec model 123, WMaxLimPct @ 40217).
|
|
# written as a single register (fn 06); the Plenticore rejects write multiple (fn 16) here.
|
|
# WMaxLim_Ena (register 40221) is enabled by default and left to the inverter
|
|
# sets the limit percent (100 % = uncurtailed), if set it takes priority over battery control.
|
|
curtail: # limit feed-in to the given percent of nominal (WMaxLimPct)
|
|
source: sunspec
|
|
{{- include "modbus" . | indent 2 }}
|
|
value: 123:WMaxLimPct
|
|
curtailed: # the limit percentage only applies while the limit is enabled
|
|
source: go
|
|
in:
|
|
- name: ena
|
|
type: bool
|
|
config:
|
|
source: sunspec
|
|
{{- include "modbus" . | indent 6 }}
|
|
value: 123:WMaxLim_Ena
|
|
- name: limit
|
|
type: float
|
|
config:
|
|
source: sunspec
|
|
{{- include "modbus" . | indent 6 }}
|
|
value: 123:WMaxLimPct
|
|
script: |
|
|
percent := 100
|
|
if ena {
|
|
percent = int(limit)
|
|
}
|
|
percent
|
|
{{- end }}
|
|
{{- if eq .usage "battery" }}
|
|
type: custom
|
|
power:
|
|
source: sunspec
|
|
{{- include "modbus" . | indent 2 }}
|
|
value: 802:W # 802 battery control
|
|
soc:
|
|
source: sunspec
|
|
{{- include "modbus" . | indent 2 }}
|
|
value: 802:SoC # 802 battery control
|
|
batterymode:
|
|
source: watchdog
|
|
timeout: {{ .watchdog }} # re-write at timeout/2
|
|
defer: true # make sure timeouts are followed on update
|
|
reset: 1 # reset watchdog on normal
|
|
set:
|
|
source: switch
|
|
switch:
|
|
- case: 1 # normal
|
|
set:
|
|
source: const
|
|
value: 0 # W (set once to reset from forced charge)
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 10 }}
|
|
register:
|
|
address: 1034 # Battery charge power (DC) setpoint, absolute [W]
|
|
type: writemultiple
|
|
encoding: {{ if (eq .endianness "big") }}float32{{ else }}float32s{{ end }}
|
|
- case: 2 # hold
|
|
set:
|
|
source: const
|
|
value: 0 # W
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 10 }}
|
|
register:
|
|
address: 1040 # Battery max. discharge power limit, absolute [W]
|
|
type: writemultiple
|
|
encoding: {{ if (eq .endianness "big") }}float32{{ else }}float32s{{ end }}
|
|
- case: 3 # charge
|
|
set:
|
|
{{- if .maxchargepower }}
|
|
source: const
|
|
value: -{{ .maxchargepower }} # W
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 10 }}
|
|
register:
|
|
address: 1034 # Battery charge power (DC) setpoint, absolute [W]
|
|
type: writemultiple
|
|
encoding: {{ if (eq .endianness "big") }}float32{{ else }}float32s{{ end }}
|
|
{{- else }}
|
|
source: error
|
|
error: ErrNotAvailable
|
|
{{- end }}
|
|
- case: 4 # holdcharge
|
|
set:
|
|
source: const
|
|
value: 0 # W
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 10 }}
|
|
register:
|
|
address: 1038 # Battery max. charge power limit, absolute [W]
|
|
type: writemultiple
|
|
encoding: {{ if (eq .endianness "big") }}float32{{ else }}float32s{{ end }}
|
|
{{- include "battery-params" . }}
|
|
{{- end }}
|