evcc-io/internal/meter/modbus.go

167 lines
3.9 KiB
Go

package meter
import (
"errors"
"fmt"
"time"
"github.com/andig/evcc/api"
"github.com/andig/evcc/util"
"github.com/andig/evcc/util/modbus"
"github.com/volkszaehler/mbmd/meters"
"github.com/volkszaehler/mbmd/meters/rs485"
"github.com/volkszaehler/mbmd/meters/sunspec"
)
// Modbus is an api.Meter implementation with configurable getters and setters.
type Modbus struct {
log *util.Logger
conn *modbus.Connection
device meters.Device
opPower modbus.Operation
opEnergy modbus.Operation
opSoC modbus.Operation
}
func init() {
registry.Add("modbus", NewModbusFromConfig)
}
//go:generate go run ../../cmd/tools/decorate.go -p meter -f decorateModbus -b api.Meter -o modbus_decorators -t "api.MeterEnergy,TotalEnergy,func() (float64, error)" -t "api.Battery,SoC,func() (float64, error)"
// NewModbusFromConfig creates api.Meter from config
func NewModbusFromConfig(other map[string]interface{}) (api.Meter, error) {
cc := struct {
Model string
modbus.Settings `mapstructure:",squash"`
Power, Energy, SoC string
Timeout time.Duration
}{
Power: "Power",
}
if err := util.DecodeOther(other, &cc); err != nil {
return nil, err
}
// assume RTU if not set and this is a known RS485 meter model
if cc.RTU == nil {
b := modbus.IsRS485(cc.Model)
cc.RTU = &b
}
log := util.NewLogger("modbus")
conn, err := modbus.NewConnection(cc.URI, cc.Device, cc.Comset, cc.Baudrate, *cc.RTU, cc.ID)
if err != nil {
return nil, err
}
// set non-default timeout
if cc.Timeout > 0 {
conn.Timeout(cc.Timeout)
}
conn.Logger(log.TRACE)
// prepare device
device, err := modbus.NewDevice(cc.Model, cc.SubDevice, *cc.RTU)
if err == nil {
err = device.Initialize(conn)
// silence Kostal implementation errors
if errors.Is(err, meters.ErrPartiallyOpened) {
err = nil
}
}
if err != nil {
return nil, err
}
m := &Modbus{
log: log,
conn: conn,
device: device,
}
cc.Power = modbus.ReadingName(cc.Power)
if err := modbus.ParseOperation(device, cc.Power, &m.opPower); err != nil {
return nil, fmt.Errorf("invalid measurement for power: %s", cc.Power)
}
// decorate energy reading
var totalEnergy func() (float64, error)
if cc.Energy != "" {
cc.Energy = modbus.ReadingName(cc.Energy)
if err := modbus.ParseOperation(device, cc.Energy, &m.opEnergy); err != nil {
return nil, fmt.Errorf("invalid measurement for energy: %s", cc.Energy)
}
totalEnergy = m.totalEnergy
}
// decorate energy reading
var soc func() (float64, error)
if cc.SoC != "" {
cc.SoC = modbus.ReadingName(cc.SoC)
if err := modbus.ParseOperation(device, cc.SoC, &m.opSoC); err != nil {
return nil, fmt.Errorf("invalid measurement for soc: %s", cc.SoC)
}
soc = m.soc
}
return decorateModbus(m, totalEnergy, soc), nil
}
// floatGetter executes configured modbus read operation and implements func() (float64, error)
func (m *Modbus) floatGetter(op modbus.Operation) (float64, error) {
var res meters.MeasurementResult
var err error
if dev, ok := m.device.(*rs485.RS485); ok {
res, err = dev.QueryOp(m.conn, op.MBMD)
}
if dev, ok := m.device.(*sunspec.SunSpec); ok {
if op.MBMD.IEC61850 != 0 {
res, err = dev.QueryOp(m.conn, op.MBMD.IEC61850)
} else {
res, err = dev.QueryPoint(
m.conn,
op.SunSpec.Model,
op.SunSpec.Block,
op.SunSpec.Point,
)
}
}
// silence NaN reading errors by assuming zero
if err != nil && errors.Is(err, meters.ErrNaN) {
res.Value = 0
err = nil
}
if err == nil {
m.log.TRACE.Printf("%+v", res)
}
return res.Value, err
}
// CurrentPower implements the api.Meter interface
func (m *Modbus) CurrentPower() (float64, error) {
return m.floatGetter(m.opPower)
}
// totalEnergy implements the api.MeterEnergy interface
func (m *Modbus) totalEnergy() (float64, error) {
return m.floatGetter(m.opEnergy)
}
// soc implements the api.Battery interface
func (m *Modbus) soc() (float64, error) {
return m.floatGetter(m.opSoC)
}