template: sofarsolar-g3
|
|
products:
|
|
- brand: SofarSolar
|
|
description:
|
|
generic: HYD 5…20K-3PH
|
|
- brand: SofarSolar
|
|
description:
|
|
generic: HYD 3…6K-EP
|
|
- brand: SofarSolar
|
|
description:
|
|
generic: SOFAR 80…136KTL
|
|
- brand: SofarSolar
|
|
description:
|
|
generic: SOFAR 5…24KTL-G3
|
|
params:
|
|
- name: usage
|
|
choice: ["grid", "pv", "battery"]
|
|
- name: modbus
|
|
choice: ["rs485", "tcpip"]
|
|
baudrate: 9600
|
|
comset: 8N1
|
|
port: 502
|
|
id: 1
|
|
- name: delay
|
|
default: 1s
|
|
- name: capacity
|
|
advanced: true
|
|
render: |
|
|
type: custom
|
|
{{- if eq .usage "grid" }}
|
|
power:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
delay: {{ .delay }}
|
|
register:
|
|
address: 0x0488 # ActivePower_PCC_Total
|
|
type: holding
|
|
decode: int16
|
|
scale: -10
|
|
currents:
|
|
- source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
delay: {{ .delay }}
|
|
register:
|
|
address: 0x0492 # Current_PCC_R
|
|
type: holding
|
|
decode: uint16
|
|
scale: 0.01
|
|
- source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
delay: {{ .delay }}
|
|
register:
|
|
address: 0x049D # Current_PCC_S
|
|
type: holding
|
|
decode: uint16
|
|
scale: 0.01
|
|
- source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
delay: {{ .delay }}
|
|
register:
|
|
address: 0x04A8 # Current_PCC_T
|
|
type: holding
|
|
decode: uint16
|
|
scale: 0.01
|
|
powers:
|
|
- source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
delay: {{ .delay }}
|
|
register:
|
|
address: 0x0493 # ActivePower_PCC_R
|
|
type: holding
|
|
decode: int16
|
|
scale: -10
|
|
- source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
delay: {{ .delay }}
|
|
register:
|
|
address: 0x049E # ActivePower_PCC_S
|
|
type: holding
|
|
decode: int16
|
|
scale: -10
|
|
- source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
delay: {{ .delay }}
|
|
register:
|
|
address: 0x04A9 # ActivePower_PCC_T
|
|
type: holding
|
|
decode: int16
|
|
scale: -10
|
|
energy:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
delay: {{ .delay }}
|
|
register:
|
|
address: 0x068E # Energy_Purchase_Total
|
|
type: holding
|
|
decode: uint32
|
|
scale: 0.1
|
|
{{- end }}
|
|
{{- if eq .usage "pv" }}
|
|
power:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
delay: {{ .delay }}
|
|
register:
|
|
address: 0x05C4 # Power_PV_Total
|
|
type: holding
|
|
decode: uint16
|
|
scale: 100
|
|
energy:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
delay: {{ .delay }}
|
|
register:
|
|
address: 0x0686 # PV_Generation_Total
|
|
type: holding
|
|
decode: uint32
|
|
scale: 0.1
|
|
{{- end }}
|
|
{{- if eq .usage "battery" }}
|
|
power:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
delay: {{ .delay }}
|
|
register:
|
|
address: 0x0606 # Power_Bat1
|
|
type: holding
|
|
decode: int16
|
|
scale: 0.01
|
|
soc:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
delay: {{ .delay }}
|
|
register:
|
|
address: 0x0608 # SOC_Bat1
|
|
type: holding
|
|
decode: uint16
|
|
energy:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
delay: {{ .delay }}
|
|
register:
|
|
address: 0x069A # Bat_Discharge_Total
|
|
type: holding
|
|
decode: uint32
|
|
scale: 0.1
|
|
{{- if ne .capacity "" }}
|
|
capacity: {{ .capacity }} # kWh
|
|
{{- end }}
|
|
{{- end }}
|