template: cg-em24
products:
- brand: Carlo Gavazzi
description:
generic: EM24
- brand: Victron
description:
generic: EM24
requirements:
description:
de: |
EM24 mit RS-485-Anschluss. Benutze die EM24_E1 für die EM24 mit Ethernet-Anschluss, denn die Definition ist nicht kompatibel.
en: |
EM24 with RS-485 connection. Use the EM24_E1 if you have an EM24_E1 with Ethernet connection, the definitions are not compatible.
params:
- name: usage
choice: ["grid", "pv", "charge"]
- name: modbus
choice: ["rs485"]
render: |
type: mbmd
{{- include "modbus" . }}
model: cgem24
{{- if ne .usage "pv" }}
power: Power
energy: Import
currents:
- CurrentL1
- CurrentL2
- CurrentL3
powers:
- PowerL1
- PowerL2
- PowerL3
{{- else }}
power: -Power
energy: Export
currents:
- -CurrentL1
- -CurrentL2
- -CurrentL3
powers:
- -PowerL1
- -PowerL2
- -PowerL3
{{- end }}
voltages:
- VoltageL1
- VoltageL2
- VoltageL3