evcc-io/templates/definition/meter/huawei-smartlogger.yaml

229 lines
6.1 KiB
YAML

template: huawei-smartlogger
products:
- brand: Huawei
description:
generic: SmartLogger
capabilities: ["battery-control"]
params:
- name: usage
choice: ["grid", "pv", "battery"]
- name: modbus
choice: ["tcpip"]
- name: maxacpower
- name: storageunit
- preset: battery-params
- name: timeout
deprecated: true
render: |
type: custom
{{- if eq .usage "grid" }}
power:
source: modbus
{{- include "modbus" . | indent 2 }}
connectdelay: 1s
register:
address: 32278 # Active power
type: holding
decode: int32
scale: 1
energy:
source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 32349 # Negative active electricity
type: holding
decode: int64
scale: 0.01
currents:
- source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 32272 # Huawei phase A grid current
type: holding
decode: int32
scale: 0.1
- source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 32274 # Huawei phase B grid current
type: holding
decode: int32
scale: 0.1
- source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 32276 # Huawei phase C grid current
type: holding
decode: int32
scale: 0.1
{{- end }}
{{- if eq .usage "pv" }}
power:
source: modbus
id: 0
uri: {{ .host }}:{{ .port }}
register:
address: 40521 # Active power
type: holding
decode: int32
energy:
source: modbus
id: 0
uri: {{ .host }}:{{ .port }}
register:
address: 40560 # E-Total
type: holding
decode: uint32
scale: 0.1
maxacpower: {{ .maxacpower }}
{{- end }}
{{- if eq .usage "battery" }}
power:
source: modbus
{{- include "modbus" . | indent 2 }}
connectdelay: 1s
register:
{{- if eq .storageunit "1" }}
address: 37001
{{- end }}
{{- if eq .storageunit "2" }}
address: 37743
{{- end }}
type: holding
decode: int32nan
scale: -1
energy:
source: modbus
{{- include "modbus" . | indent 2 }}
register:
{{- if eq .storageunit "1" }}
address: 37068 # [Energy storage unit 1] Total discharge
{{- end }}
{{- if eq .storageunit "2" }}
address: 37755 # [Energy storage unit 2] Total discharge
{{- end }}
type: holding
decode: uint32nan
scale: 0.01
soc:
source: modbus
{{- include "modbus" . | indent 2 }}
register:
{{- if eq .storageunit "1" }}
address: 37004
{{- end }}
{{- if eq .storageunit "2" }}
address: 37738
{{- end }}
type: holding
decode: uint16nan
scale: 0.1
batterymode:
source: watchdog
timeout: 30s
reset: 1 # reset watchdog on normal
set:
source: switch
switch:
- case: 1 # normal
set:
source: const
value: 0 # stop
set:
source: modbus
{{- include "modbus" . | indent 10 }}
register:
address: 47100 # Forcible charge/discharge
type: writesingle
encoding: uint16
- case: 2 # hold
set:
source: sequence
set:
- source: const
value: 2 # discharge
set:
source: modbus
{{- include "modbus" . | indent 12 }}
register:
address: 47100 # Forcible charge/discharge
type: writesingle
encoding: uint16
- source: const
value: 0 # duration
set:
source: modbus
{{- include "modbus" . | indent 12 }}
register:
address: 47246 # Forcible charge/discharge setting mode
type: writesingle
encoding: uint16
- source: const
value: 1 # Minute
set:
source: modbus
{{- include "modbus" . | indent 12 }}
register:
address: 47083 # Forced charging and discharging period
type: writesingle
encoding: uint16
- source: const
value: 0 # W
set:
source: modbus
{{- include "modbus" . | indent 12 }}
register:
address: 47249 # Forcible discharge power
type: writemultiple
encoding: uint32
- case: 3 # charge
set:
source: sequence
set:
- source: const
value: 1 # charge
set:
source: modbus
{{- include "modbus" . | indent 12 }}
register:
address: 47100 # Forcible charge/discharge
type: writesingle
encoding: uint16
- source: const
value: 0 # duration
set:
source: modbus
{{- include "modbus" . | indent 12 }}
register:
address: 47246 # Forcible charge/discharge setting mode
type: writesingle
encoding: uint16
- source: const
value: 1 # Minute
set:
source: modbus
{{- include "modbus" . | indent 12 }}
register:
address: 47083 # Forced charging and discharging period
type: writesingle
encoding: uint16
- source: const
value: 2500 # W
set:
source: modbus
{{- include "modbus" . | indent 12 }}
register:
address: 47247 # Forcible charge power
type: writemultiple
encoding: uint32
- source: const
value: 1 # Enable
set:
source: modbus
{{- include "modbus" . | indent 12 }}
register:
address: 47087 # Charge from grid
type: writesingle
encoding: uint16
{{- include "battery-params" . }}
{{- end }}