evcc-io/templates/definition/meter/sma-datamanager.yaml

102 lines
2.7 KiB
YAML

template: sma-data-manager
covers: ["sma-data-manager-m-lite"]
products:
- brand: SMA
description:
generic: Data Manager
requirements:
description:
de: In der Weboberfläche des SMA Data Manager muss im Bereich "Externe Kommunikation" der Schalter "Modbus Server aktivieren" eingeschaltet sein.
en: In the web interface of the SMA Data Manager you need to activate "Modbus Server activated" in the section "External communication".
params:
- name: usage
choice: ["grid", "pv", "battery"]
- name: modbus
choice: ["tcpip"]
id: 2
- preset: battery-params
render: |
type: custom
{{- if eq .usage "pv" }}
power:
source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 30775 # Aktuelle PV-Einspeisewirkleistung über alle Außenleiter, W
type: holding
decode: int32nan
energy:
source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 30513 # Total eingespeiste Energie auf allen Außenleitern, Wh
type: holding
decode: uint64nan
scale: 0.001
{{- end }}
{{- if eq .usage "grid" }}
power:
source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 31249 # Grid, W
type: holding
decode: int32nan
scale: -1
currents:
- source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 31535 # Anlagenstrom Phase L1 am PCC, mA
type: holding
decode: int32nan
scale: -0.001
- source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 31537 # Anlagenstrom Phase L2 am PCC, mA
type: holding
decode: int32nan
scale: -0.001
- source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 31539 # Anlagenstrom Phase L3 am PCC, mA
type: holding
decode: int32nan
scale: -0.001
{{- end }}
{{- if eq .usage "battery" }}
power:
source: calc
add:
- source: modbus
{{- include "modbus" . | indent 4 }}
register:
address: 31393 # Momentane Batterieladung, W
type: holding
decode: uint32nan
scale: -1
- source: modbus
{{- include "modbus" . | indent 4 }}
register:
address: 31395 # Momentane Batterieentladung, W
type: holding
decode: uint32nan
energy:
source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 31401 # Batterieentladung, Wh
type: holding
decode: uint64nan
scale: 0.001
soc:
source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 30845 # Battery Soc, %
type: holding
decode: uint32nan
{{- include "battery-params" . }}
{{- end }}