109 lines
3.6 KiB
YAML
109 lines
3.6 KiB
YAML
template: smartfox-em2
|
|
products:
|
|
- brand: Smartfox
|
|
description:
|
|
generic: Pro
|
|
- brand: Smartfox
|
|
description:
|
|
generic: Pro 2
|
|
- brand: Smartfox
|
|
description:
|
|
generic: Pro Light
|
|
- brand: Smartfox
|
|
description:
|
|
generic: Pro Light 2
|
|
- brand: Smartfox
|
|
description:
|
|
generic: Light (EM2 firmware)
|
|
requirements:
|
|
description:
|
|
de: |
|
|
`aux` kann für die Leistung der Warmwasserbereitung verwendet werden.
|
|
en: |
|
|
`aux` can be used for water heating power.
|
|
params:
|
|
- name: usage
|
|
choice: ["grid", "pv", "aux"]
|
|
- name: host
|
|
- name: cache
|
|
advanced: true
|
|
default: 1s
|
|
render: |
|
|
{{- define "uri" -}}
|
|
http://{{ .host }}/values.xml
|
|
{{- end }}
|
|
type: custom
|
|
# jq: parse json generated from response values.xml (https://jqplay.org is your friend to test queries)
|
|
{{- if eq .usage "grid" }}
|
|
power: # grid power in W
|
|
source: http
|
|
cache: {{ .cache }}
|
|
uri: {{ include "uri" . }}
|
|
jq: .values.value[] | select(.attrid=="detailsPowerValue")."#content" | rtrimstr(" W")
|
|
energy: # grid energy in kWh
|
|
source: http
|
|
cache: {{ .cache }}
|
|
uri: {{ include "uri" . }}
|
|
jq: .values.value[] | select(.attrid=="energyValue")."#content" | rtrimstr(" kWh")
|
|
voltages: # grid voltages in V
|
|
- source: http
|
|
cache: {{ .cache }}
|
|
uri: {{ include "uri" . }}
|
|
jq: .values.value[] | select(.attrid=="voltageL1Value")."#content" | rtrimstr(" V")
|
|
- source: http
|
|
cache: {{ .cache }}
|
|
uri: {{ include "uri" . }}
|
|
jq: .values.value[] | select(.attrid=="voltageL2Value")."#content" | rtrimstr(" V")
|
|
- source: http
|
|
cache: {{ .cache }}
|
|
uri: {{ include "uri" . }}
|
|
jq: .values.value[] | select(.attrid=="voltageL3Value")."#content" | rtrimstr(" V")
|
|
currents: # grid currents in A
|
|
- source: http
|
|
cache: {{ .cache }}
|
|
uri: {{ include "uri" . }}
|
|
jq: .values.value[] | select(.attrid=="ampereL1Value")."#content" | rtrimstr(" A")
|
|
- source: http
|
|
cache: {{ .cache }}
|
|
uri: {{ include "uri" . }}
|
|
jq: .values.value[] | select(.attrid=="ampereL2Value")."#content" | rtrimstr(" A")
|
|
- source: http
|
|
cache: {{ .cache }}
|
|
uri: {{ include "uri" . }}
|
|
jq: .values.value[] | select(.attrid=="ampereL3Value")."#content" | rtrimstr(" A")
|
|
powers: # grid powers in W
|
|
- source: http
|
|
cache: {{ .cache }}
|
|
uri: {{ include "uri" . }}
|
|
jq: .values.value[] | select(.attrid=="powerL1Value")."#content" | rtrimstr(" W")
|
|
- source: http
|
|
cache: {{ .cache }}
|
|
uri: {{ include "uri" . }}
|
|
jq: .values.value[] | select(.attrid=="powerL2Value")."#content" | rtrimstr(" W")
|
|
- source: http
|
|
cache: {{ .cache }}
|
|
uri: {{ include "uri" . }}
|
|
jq: .values.value[] | select(.attrid=="powerL3Value")."#content" | rtrimstr(" W")
|
|
{{- end }}
|
|
{{- if eq .usage "pv" }}
|
|
# PV power and energy values are delivered for each inverter, we select them via regex and sum the values
|
|
power: # PV power in W
|
|
source: http
|
|
cache: {{ .cache }}
|
|
uri: {{ include "uri" . }}
|
|
jq: '[.values.value[] | select(.attrid|test("wr\\d+PowerValue"))."#content" | rtrimstr(" kW") | tonumber] | add'
|
|
scale: 1000 # wr1PowerValue, ..., wr5PowerValue are in kW
|
|
energy: # PV energy in kWh
|
|
source: http
|
|
cache: {{ .cache }}
|
|
uri: {{ include "uri" . }}
|
|
jq: '[.values.value[] | select(.attrid|test("wr\\d+EnergyValue"))."#content" | rtrimstr(" kWh") | tonumber] | add'
|
|
{{- end }}
|
|
{{- if eq .usage "aux" }}
|
|
power: # heating power in W
|
|
source: http
|
|
cache: {{ .cache }}
|
|
uri: {{ include "uri" . }}
|
|
jq: .values.value[] | select(.attrid=="htPowerMeasValue")."#content" | rtrimstr(" kW")
|
|
scale: 1000
|
|
{{- end }}
|