204 lines
5.7 KiB
YAML
204 lines
5.7 KiB
YAML
template: solaredge-hybrid
|
|
products:
|
|
- brand: SolarEdge
|
|
description:
|
|
generic: Hybrid Inverter
|
|
capabilities: ["battery-control"]
|
|
requirements:
|
|
description:
|
|
de: |
|
|
Nur ein System kann und darf zeitgleich eine Modbus TCP-Verbindung zum Wechselrichter haben!
|
|
Für die optionale Batteriesteuerung muss StorageConf_CtrlMode (0xE004) auf 4 "Remote" stehen.
|
|
en: |
|
|
Only one system can and may have a Modbus TCP connection to the inverter at the same time!
|
|
For optional battery control, StorageConf_CtrlMode (0xE004) must be set to 4 "Remote".
|
|
params:
|
|
- name: usage
|
|
choice: ["grid", "pv", "battery"]
|
|
- name: modbus
|
|
choice: ["tcpip", "rs485"]
|
|
id: 1
|
|
port: 1502
|
|
- name: maxacpower
|
|
- preset: battery-params
|
|
- name: maxdischargepower
|
|
default: 5000
|
|
- name: watchdog
|
|
type: duration
|
|
default: 60s
|
|
advanced: true
|
|
- name: timeout
|
|
deprecated: true
|
|
render: |
|
|
type: custom
|
|
{{- if eq .usage "grid" }}
|
|
power:
|
|
source: sunspec
|
|
{{- include "modbus" . | indent 2 }}
|
|
subdevice: 1 # Metering device
|
|
value: 203:W
|
|
scale: -1
|
|
energy:
|
|
source: sunspec
|
|
{{- include "modbus" . | indent 2 }}
|
|
subdevice: 1 # Metering device
|
|
value: 203:TotWhImp
|
|
scale: 0.001
|
|
currents:
|
|
- source: sunspec
|
|
{{- include "modbus" . | indent 4 }}
|
|
subdevice: 1 # Metering device
|
|
value: 203:AphA
|
|
- source: sunspec
|
|
{{- include "modbus" . | indent 4 }}
|
|
subdevice: 1 # Metering device
|
|
value: 203:AphB
|
|
- source: sunspec
|
|
{{- include "modbus" . | indent 4 }}
|
|
subdevice: 1 # Metering device
|
|
value: 203:AphC
|
|
voltages:
|
|
- source: sunspec
|
|
{{- include "modbus" . | indent 4 }}
|
|
subdevice: 1 # Metering device
|
|
value: 203:PhVphA
|
|
- source: sunspec
|
|
{{- include "modbus" . | indent 4 }}
|
|
subdevice: 1 # Metering device
|
|
value: 203:PhVphB
|
|
- source: sunspec
|
|
{{- include "modbus" . | indent 4 }}
|
|
subdevice: 1 # Metering device
|
|
value: 203:PhVphC
|
|
powers:
|
|
- source: sunspec
|
|
{{- include "modbus" . | indent 4 }}
|
|
subdevice: 1 # Metering device
|
|
value: 203:WphA
|
|
scale: -1
|
|
- source: sunspec
|
|
{{- include "modbus" . | indent 4 }}
|
|
subdevice: 1 # Metering device
|
|
value: 203:WphB
|
|
scale: -1
|
|
- source: sunspec
|
|
{{- include "modbus" . | indent 4 }}
|
|
subdevice: 1 # Metering device
|
|
value: 203:WphC
|
|
scale: -1
|
|
{{- end }}
|
|
{{- if eq .usage "pv" }}
|
|
power:
|
|
source: calc
|
|
add:
|
|
- source: sunspec
|
|
{{- include "modbus" . | indent 6 }}
|
|
value:
|
|
- 101:DCW
|
|
- 103:DCW
|
|
- source: modbus
|
|
{{- include "modbus" . | indent 6 }}
|
|
register:
|
|
address: 62836 # Battery 1 Instantaneous Power
|
|
type: holding
|
|
decode: float32nans
|
|
energy:
|
|
source: sunspec
|
|
{{- include "modbus" . | indent 2 }}
|
|
value:
|
|
- 101:WH
|
|
- 103:WH
|
|
scale: 0.001
|
|
maxacpower: {{ .maxacpower }} # W
|
|
{{- end }}
|
|
{{- if eq .usage "battery" }}
|
|
power:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
register:
|
|
address: 0xE174 # Battery 1 Instantaneous Power
|
|
type: holding
|
|
decode: float32nans
|
|
scale: -1
|
|
soc:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
register:
|
|
address: 0xE184 # Battery 1 State of Energy (SOE)
|
|
type: holding
|
|
decode: float32nans
|
|
batterymode:
|
|
source: watchdog
|
|
timeout: {{ .watchdog }}
|
|
reset: 1 # reset watchdog on normal
|
|
set:
|
|
source: switch
|
|
switch:
|
|
- case: 1 # normal
|
|
set:
|
|
source: sequence
|
|
set:
|
|
- source: const
|
|
value: 7 # Maximize self-consumption
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 12 }}
|
|
register:
|
|
address: 0xE00D # StorageRemoteCtrl_CommandMode
|
|
type: writesingle
|
|
encoding: uint16
|
|
- source: const
|
|
value: {{ .maxdischargepower }} # W
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 12 }}
|
|
register:
|
|
address: 0xE010 # StorageRemoteCtrl_DischargeLimit
|
|
type: writemultiple
|
|
encoding: float32s
|
|
- case: 2 # hold
|
|
set:
|
|
source: sequence
|
|
set:
|
|
- source: const
|
|
value: 7 # Maximize self-consumption
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 12 }}
|
|
register:
|
|
address: 0xE00D # StorageRemoteCtrl_CommandMode
|
|
type: writesingle
|
|
encoding: uint16
|
|
- source: const
|
|
value: 0 # W
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 12 }}
|
|
register:
|
|
address: 0xE010 # StorageRemoteCtrl_DischargeLimit
|
|
type: writemultiple
|
|
encoding: float32s
|
|
- case: 3 # charge
|
|
set:
|
|
source: sequence
|
|
set:
|
|
- source: const
|
|
value: 3 # Charge from PV+AC according to the max battery power
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 12 }}
|
|
register:
|
|
address: 0xE00D # StorageRemoteCtrl_CommandMode
|
|
type: writesingle
|
|
encoding: uint16
|
|
- source: const
|
|
value: 0 # W
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 12 }}
|
|
register:
|
|
address: 0xE010 # StorageRemoteCtrl_DischargeLimit
|
|
type: writemultiple
|
|
encoding: float32s
|
|
{{- include "battery-params" . }}
|
|
{{- end }}
|