template: wattsonic
|
|
products:
|
|
- brand: Wattsonic
|
|
- brand: Sunway
|
|
- brand: Solinteng
|
|
- brand: A-Tronix
|
|
- brand: St-ems
|
|
capabilities: ["battery-control"]
|
|
params:
|
|
- name: usage
|
|
choice: ["grid", "pv", "battery"]
|
|
- name: modbus
|
|
choice: ["rs485"]
|
|
port: 502
|
|
id: 247
|
|
- preset: battery-params
|
|
- name: delay
|
|
default: 100ms
|
|
advanced: true
|
|
render: |
|
|
type: custom
|
|
{{- if eq .usage "grid" }}
|
|
power: # power (W)
|
|
source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
delay: {{ .delay }}
|
|
register:
|
|
address: 11000 # Total Power on Meter
|
|
type: holding
|
|
decode: int32
|
|
scale: -1
|
|
currents:
|
|
- source: modbus
|
|
{{- include "modbus" . | indent 4 }}
|
|
delay: {{ .delay }}
|
|
register:
|
|
address: 11010 # Grid Phase A Current
|
|
type: holding
|
|
decode: uint16
|
|
scale: 0.1
|
|
- source: modbus
|
|
{{- include "modbus" . | indent 4 }}
|
|
delay: {{ .delay }}
|
|
register:
|
|
address: 11012 # Grid Phase B Current
|
|
type: holding
|
|
decode: uint16
|
|
scale: 0.1
|
|
- source: modbus
|
|
{{- include "modbus" . | indent 4 }}
|
|
delay: {{ .delay }}
|
|
register:
|
|
address: 11014 # Grid Phase C Current
|
|
type: holding
|
|
decode: uint16
|
|
scale: 0.1
|
|
powers:
|
|
- source: modbus
|
|
{{- include "modbus" . | indent 4 }}
|
|
delay: {{ .delay }}
|
|
register:
|
|
address: 10994 # Phase A Power on Meter
|
|
type: holding
|
|
decode: int32
|
|
scale: -1
|
|
- source: modbus
|
|
{{- include "modbus" . | indent 4 }}
|
|
delay: {{ .delay }}
|
|
register:
|
|
address: 10996 # Phase B Power on Meter
|
|
type: holding
|
|
decode: int32
|
|
scale: -1
|
|
- source: modbus
|
|
{{- include "modbus" . | indent 4 }}
|
|
delay: {{ .delay }}
|
|
register:
|
|
address: 10998 # Phase C Power on Meter
|
|
type: holding
|
|
decode: int32
|
|
scale: -1
|
|
{{- end }}
|
|
{{- if eq .usage "pv" }}
|
|
power: # power (W)
|
|
source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
delay: {{ .delay }}
|
|
register:
|
|
address: 11028 # PV Input Total Power
|
|
type: holding
|
|
decode: int32
|
|
{{- end }}
|
|
{{- if eq .usage "battery" }}
|
|
power: # power (W)
|
|
source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
delay: {{ .delay }}
|
|
register:
|
|
address: 40258 # Total_Backup_P
|
|
type: holding
|
|
decode: int32
|
|
soc:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
delay: {{ .delay }}
|
|
scale: 0.01
|
|
register:
|
|
address: 43000 # SOC
|
|
type: holding
|
|
decode: int16
|
|
limitsoc:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
delay: {{ .delay }}
|
|
register:
|
|
address: 52503 # min soc
|
|
type: writeholding
|
|
encoding: uint16
|
|
{{- include "battery-params" . }}
|
|
{{- end }}
|