256 lines
6.2 KiB
Vue
256 lines
6.2 KiB
Vue
<template>
|
|
<FormRow
|
|
v-if="showConnectionOptions"
|
|
id="modbusTcpIp"
|
|
label="Modbus Connection"
|
|
:help="
|
|
connection === 'tcpip'
|
|
? 'The device is addressable from evcc via LAN/Wifi.'
|
|
: 'The device is diretly connected to evcc via a RS485 interface.'
|
|
"
|
|
>
|
|
<div class="btn-group" role="group">
|
|
<input
|
|
id="modbusTcpIp"
|
|
v-model="connection"
|
|
type="radio"
|
|
class="btn-check"
|
|
name="modbusConnection"
|
|
value="tcpip"
|
|
tabindex="0"
|
|
autocomplete="off"
|
|
/>
|
|
<label class="btn btn-outline-primary" for="modbusTcpIp">Network</label>
|
|
<input
|
|
id="modbusSerial"
|
|
v-model="connection"
|
|
type="radio"
|
|
class="btn-check"
|
|
name="modbusConnection"
|
|
value="serial"
|
|
tabindex="0"
|
|
autocomplete="off"
|
|
/>
|
|
<label class="btn btn-outline-primary" for="modbusSerial">Serial / USB</label>
|
|
</div>
|
|
</FormRow>
|
|
<FormRow id="modbusId" label="Modbus ID">
|
|
<PropertyField
|
|
id="modbusId"
|
|
property="id"
|
|
type="Int"
|
|
class="me-2"
|
|
required
|
|
:model-value="id || defaultId || 1"
|
|
@change="$emit('update:id', $event.target.value)"
|
|
/>
|
|
</FormRow>
|
|
<div v-if="connection === 'tcpip'">
|
|
<FormRow id="modbusHost" label="IP address or hostname" help="Example: 192.0.2.2">
|
|
<PropertyField
|
|
id="modbusHost"
|
|
property="host"
|
|
type="String"
|
|
class="me-2"
|
|
required
|
|
:model-value="host"
|
|
@change="$emit('update:host', $event.target.value)"
|
|
/>
|
|
</FormRow>
|
|
<FormRow id="modbusPort" label="Port">
|
|
<PropertyField
|
|
id="modbusPort"
|
|
property="port"
|
|
type="Int"
|
|
class="me-2 w-50"
|
|
required
|
|
:model-value="port || defaultPort || 502"
|
|
@change="$emit('update:port', $event.target.value)"
|
|
/>
|
|
</FormRow>
|
|
<FormRow
|
|
v-if="showProtocolOptions"
|
|
id="modbusTcp"
|
|
label="Modbus Protocol"
|
|
:help="
|
|
protocol === 'tcp'
|
|
? 'Device has native LAN/Wifi support or is connected through a RS485 to Ethernet adapter with protocol translation.'
|
|
: 'Connection through a RS485 to Ethernet adapter without protocol translation.'
|
|
"
|
|
>
|
|
<div class="btn-group" role="group">
|
|
<input
|
|
id="modbusTcp"
|
|
v-model="protocol"
|
|
type="radio"
|
|
class="btn-check"
|
|
name="modbusProtocol"
|
|
value="tcp"
|
|
tabindex="0"
|
|
autocomplete="off"
|
|
/>
|
|
<label class="btn btn-outline-primary" for="modbusTcp">TCP</label>
|
|
<input
|
|
id="modbusRtu"
|
|
v-model="protocol"
|
|
type="radio"
|
|
class="btn-check"
|
|
name="modbusProtocol"
|
|
value="rtu"
|
|
tabindex="0"
|
|
autocomplete="off"
|
|
/>
|
|
<label class="btn btn-outline-primary" for="modbusRtu">RTU</label>
|
|
</div>
|
|
</FormRow>
|
|
</div>
|
|
<div v-else>
|
|
<FormRow id="modbusDevice" label="Device name" help="Example: /dev/ttyUSB0">
|
|
<PropertyField
|
|
id="modbusDevice"
|
|
property="device"
|
|
type="String"
|
|
class="me-2"
|
|
required
|
|
:model-value="device"
|
|
@change="$emit('update:device', $event.target.value)"
|
|
/>
|
|
</FormRow>
|
|
<FormRow id="modbusBaudrate" label="Baudrate">
|
|
<PropertyField
|
|
id="modbusBaudrate"
|
|
property="baudrate"
|
|
type="Choice"
|
|
class="me-2 w-50"
|
|
:choice="baudrateOptions"
|
|
required
|
|
:model-value="baudrate || defaultBaudrate"
|
|
@change="$emit('update:baudrate', $event.target.value)"
|
|
/>
|
|
</FormRow>
|
|
<FormRow id="modbusComset" label="ComSet">
|
|
<PropertyField
|
|
id="modbusComset"
|
|
property="comset"
|
|
type="Choice"
|
|
class="me-2 w-50"
|
|
:choice="comsetOptions"
|
|
required
|
|
:model-value="comset || defaultComset || '8N1'"
|
|
@change="$emit('update:comset', $event.target.value)"
|
|
/>
|
|
</FormRow>
|
|
</div>
|
|
</template>
|
|
|
|
<script lang="ts">
|
|
import { defineComponent } from "vue";
|
|
import FormRow from "./FormRow.vue";
|
|
import PropertyField from "./PropertyField.vue";
|
|
import type { PropType } from "vue";
|
|
|
|
type Capability = "rs485" | "tcpip";
|
|
type Modbus = "rs485serial" | "rs485tcpip" | "tcpip";
|
|
type ConnectionOption = "tcpip" | "serial";
|
|
type ProtocolOption = "tcp" | "rtu";
|
|
|
|
export default defineComponent({
|
|
name: "Modbus",
|
|
components: { FormRow, PropertyField },
|
|
props: {
|
|
capabilities: {
|
|
type: Array as PropType<Capability[]>,
|
|
default: () => [],
|
|
},
|
|
modbus: String as PropType<Modbus>,
|
|
host: String,
|
|
port: [Number, String],
|
|
id: [Number, String],
|
|
baudrate: [Number, String],
|
|
comset: String,
|
|
device: String,
|
|
defaultPort: Number,
|
|
defaultId: Number,
|
|
defaultComset: String,
|
|
defaultBaudrate: Number,
|
|
},
|
|
emits: [
|
|
"update:modbus",
|
|
"update:id",
|
|
"update:host",
|
|
"update:port",
|
|
"update:device",
|
|
"update:baudrate",
|
|
"update:comset",
|
|
],
|
|
data(): { connection: ConnectionOption; protocol: ProtocolOption } {
|
|
return {
|
|
connection: "tcpip",
|
|
protocol: "tcp",
|
|
};
|
|
},
|
|
computed: {
|
|
selectedModbus(): Modbus {
|
|
if (this.connection === "serial") {
|
|
return "rs485serial";
|
|
}
|
|
return this.protocol === "rtu" ? "rs485tcpip" : "tcpip";
|
|
},
|
|
showConnectionOptions() {
|
|
return this.capabilities.includes("rs485");
|
|
},
|
|
showProtocolOptions() {
|
|
return this.connection === "tcpip" && this.capabilities.includes("rs485");
|
|
},
|
|
comsetOptions() {
|
|
return ["8N1", "8E1"].map((v) => {
|
|
return { key: v, name: v };
|
|
});
|
|
},
|
|
baudrateOptions() {
|
|
return [1200, 9600, 19200, 38400, 57600, 115200].map((v) => {
|
|
return { key: v, name: `${v}` };
|
|
});
|
|
},
|
|
},
|
|
watch: {
|
|
selectedModbus(newValue: Modbus) {
|
|
this.$emit("update:modbus", newValue);
|
|
},
|
|
options(newValue: Capability[]) {
|
|
this.setProtocolByCapabilities(newValue);
|
|
this.$emit("update:modbus", this.selectedModbus);
|
|
},
|
|
modbus(newValue: Modbus) {
|
|
if (newValue) {
|
|
this.setConnectionAndProtocolByModbus(newValue);
|
|
}
|
|
},
|
|
},
|
|
mounted() {
|
|
this.setConnectionAndProtocolByModbus(this.modbus);
|
|
this.$emit("update:modbus", this.selectedModbus);
|
|
},
|
|
methods: {
|
|
setProtocolByCapabilities(capabilities: Capability[]) {
|
|
this.protocol = capabilities.includes("tcpip") ? "tcp" : "rtu";
|
|
},
|
|
setConnectionAndProtocolByModbus(modbus?: Modbus) {
|
|
switch (modbus) {
|
|
case "rs485serial":
|
|
this.connection = "serial";
|
|
this.protocol = "rtu";
|
|
break;
|
|
case "rs485tcpip":
|
|
this.connection = "tcpip";
|
|
this.protocol = "rtu";
|
|
break;
|
|
case "tcpip":
|
|
this.connection = "tcpip";
|
|
this.protocol = "tcp";
|
|
break;
|
|
}
|
|
},
|
|
},
|
|
});
|
|
</script>
|