evcc-io/evcc.dist.yaml

40 lines
1.1 KiB
YAML

uri: 0.0.0.0:7070 # uri for ui
interval: 10s # control cycle interval
mqtt:
broker: localhost:1883 # mqtt broker address
# user:
# password:
meters:
- name: grid
power: # power reading
type: mqtt # use mqtt
topic: mbmd/sdm1-1/Power # mqtt topic
timeout: 10s # don't use older values
- name: pv
power:
type: mqtt
topic: mbmd/sdm1-2/Power
timeout: 10s # don't use older values
- name: charge
power:
type: script # use script
cmd: /bin/sh -c "echo 0" # actual command
timeout: 3s # kill script after 3 seconds
chargers:
- name: wallbe
type: wallbe # Wallbe charger using Phoenix Contact controller
uri: 192.168.0.8:502 # ModBus address
loadpoints:
- name: lp1 # name for logging
steepness: 1 # raise/lower charge current in 1A steps
guardduration: 10m # switch charger contactor not more often than this (default 10m)
maxcurrent: 16 # maximum charge current (default 16A)
phases: 3 # ev phases (default 3)
charger: wallbe # charger
gridmeter: grid # grid meter
pvmeter: pv # pv meter
chargemeter: charge # charge meter