171 lines
3.9 KiB
Go
171 lines
3.9 KiB
Go
package provider
|
|
|
|
import (
|
|
"errors"
|
|
"fmt"
|
|
"math"
|
|
|
|
"github.com/andig/evcc/util"
|
|
"github.com/andig/evcc/util/modbus"
|
|
"github.com/volkszaehler/mbmd/meters"
|
|
"github.com/volkszaehler/mbmd/meters/rs485"
|
|
"github.com/volkszaehler/mbmd/meters/sunspec"
|
|
)
|
|
|
|
// Modbus implements modbus RTU and TCP access
|
|
type Modbus struct {
|
|
log *util.Logger
|
|
conn *modbus.Connection
|
|
device meters.Device
|
|
op modbus.Operation
|
|
scale float64
|
|
}
|
|
|
|
// NewModbusFromConfig creates Modbus plugin
|
|
func NewModbusFromConfig(other map[string]interface{}) (*Modbus, error) {
|
|
cc := struct {
|
|
Model string
|
|
modbus.Settings `mapstructure:",squash"`
|
|
Register modbus.Register
|
|
Value string
|
|
Scale float64
|
|
}{
|
|
Scale: 1,
|
|
}
|
|
|
|
if err := util.DecodeOther(other, &cc); err != nil {
|
|
return nil, err
|
|
}
|
|
|
|
// assume RTU if not set and this is a known RS485 meter model
|
|
if cc.RTU == nil {
|
|
b := modbus.IsRS485(cc.Model)
|
|
cc.RTU = &b
|
|
}
|
|
|
|
conn, err := modbus.NewConnection(cc.URI, cc.Device, cc.Comset, cc.Baudrate, *cc.RTU, cc.ID)
|
|
if err != nil {
|
|
return nil, err
|
|
}
|
|
|
|
log := util.NewLogger("modbus")
|
|
conn.Logger(log.TRACE)
|
|
|
|
var device meters.Device
|
|
var op modbus.Operation
|
|
|
|
if cc.Value != "" && cc.Register.Decode != "" {
|
|
return nil, errors.New("modbus cannot have value and register both")
|
|
}
|
|
|
|
if cc.Value == "" && cc.Register.Decode == "" {
|
|
log.WARN.Println("missing modbus value or register - assuming Power")
|
|
cc.Value = "Power"
|
|
}
|
|
|
|
// model + value configured
|
|
if cc.Value != "" {
|
|
cc.Value = modbus.ReadingName(cc.Value)
|
|
if err := modbus.ParseOperation(device, cc.Value, &op); err != nil {
|
|
return nil, fmt.Errorf("invalid value %s", cc.Value)
|
|
}
|
|
|
|
// if sunspec reading configured make sure model is defined or device won't be initalized
|
|
if op.SunSpec.Point != "" && cc.Model == "" {
|
|
cc.Model = "SunSpec"
|
|
}
|
|
}
|
|
|
|
// register configured
|
|
if cc.Register.Decode != "" {
|
|
if op.MBMD, err = modbus.RegisterOperation(cc.Register); err != nil {
|
|
return nil, err
|
|
}
|
|
}
|
|
|
|
// model configured
|
|
if cc.Model != "" {
|
|
device, err = modbus.NewDevice(cc.Model, cc.SubDevice, *cc.RTU)
|
|
|
|
// prepare device
|
|
if err == nil {
|
|
err = device.Initialize(conn)
|
|
|
|
// silence KOSTAL implementation errors
|
|
if errors.Is(err, meters.ErrPartiallyOpened) {
|
|
err = nil
|
|
}
|
|
}
|
|
}
|
|
|
|
if err != nil {
|
|
return nil, err
|
|
}
|
|
|
|
mb := &Modbus{
|
|
log: log,
|
|
conn: conn,
|
|
device: device,
|
|
op: op,
|
|
scale: cc.Scale,
|
|
}
|
|
return mb, nil
|
|
}
|
|
|
|
// FloatGetter executes configured modbus read operation and implements func() (float64, error)
|
|
func (m *Modbus) FloatGetter() (float64, error) {
|
|
var res meters.MeasurementResult
|
|
var err error
|
|
|
|
// if funccode is configured, execute the read directly
|
|
if op := m.op.MBMD; op.FuncCode != 0 {
|
|
var bytes []byte
|
|
switch op.FuncCode {
|
|
case rs485.ReadHoldingReg:
|
|
bytes, err = m.conn.ReadHoldingRegisters(op.OpCode, op.ReadLen)
|
|
case rs485.ReadInputReg:
|
|
bytes, err = m.conn.ReadInputRegisters(op.OpCode, op.ReadLen)
|
|
default:
|
|
return 0, fmt.Errorf("unknown function code %d", op.FuncCode)
|
|
}
|
|
|
|
if err != nil {
|
|
return 0, fmt.Errorf("read failed: %v", err)
|
|
}
|
|
|
|
return m.scale * op.Transform(bytes), nil
|
|
}
|
|
|
|
// if funccode is not configured, try find the reading on sunspec
|
|
if dev, ok := m.device.(*sunspec.SunSpec); ok {
|
|
if m.op.MBMD.IEC61850 != 0 {
|
|
// client := m.conn.ModbusClient()
|
|
res, err = dev.QueryOp(m.conn, m.op.MBMD.IEC61850)
|
|
} else {
|
|
res, err = dev.QueryPoint(
|
|
m.conn,
|
|
m.op.SunSpec.Model,
|
|
m.op.SunSpec.Block,
|
|
m.op.SunSpec.Point,
|
|
)
|
|
}
|
|
}
|
|
|
|
// silence NaN reading errors by assuming zero
|
|
if err != nil && errors.Is(err, meters.ErrNaN) {
|
|
res.Value = 0
|
|
err = nil
|
|
}
|
|
|
|
if err == nil {
|
|
m.log.TRACE.Printf("%+v", res)
|
|
}
|
|
|
|
return m.scale * res.Value, err
|
|
}
|
|
|
|
// IntGetter executes configured modbus read operation and implements provider.IntGetter
|
|
func (m *Modbus) IntGetter() (int64, error) {
|
|
res, err := m.FloatGetter()
|
|
return int64(math.Round(res)), err
|
|
}
|