template: solis-hybrid-s
|
||
products:
|
||
- brand: Ginlong
|
||
description:
|
||
generic: Solis Hybrid Inverter (S Series)
|
||
params:
|
||
- name: usage
|
||
choice: ["grid", "pv", "battery"]
|
||
allinone: true
|
||
- name: modbus
|
||
choice: ["rs485"]
|
||
baudrate: 9600
|
||
id: 1
|
||
- name: capacity
|
||
advanced: true
|
||
- name: maxacpower
|
||
render: |
|
||
type: custom
|
||
{{- if eq .usage "grid" }}
|
||
power:
|
||
source: modbus
|
||
{{- include "modbus" . | indent 2 }}
|
||
register:
|
||
address: 33263 # Meter total active power
|
||
type: input
|
||
decode: int32
|
||
scale: -1
|
||
energy:
|
||
source: modbus
|
||
{{- include "modbus" . | indent 2 }}
|
||
register:
|
||
address: 33283 # Meter total active energy from grid
|
||
type: input
|
||
decode: uint32
|
||
scale: 0.01
|
||
currents:
|
||
- source: modbus
|
||
{{- include "modbus" . | indent 2 }}
|
||
register:
|
||
address: 33252 # Meter ac current A
|
||
type: input
|
||
decode: uint16
|
||
scale: 0.01
|
||
- source: modbus
|
||
{{- include "modbus" . | indent 2 }}
|
||
register:
|
||
address: 33254 # Meter ac current B
|
||
type: input
|
||
decode: uint16
|
||
scale: 0.01
|
||
- source: modbus
|
||
{{- include "modbus" . | indent 2 }}
|
||
register:
|
||
address: 33256 # Meter ac current C
|
||
type: input
|
||
decode: uint16
|
||
scale: 0.01
|
||
powers:
|
||
- source: modbus
|
||
{{- include "modbus" . | indent 2 }}
|
||
register:
|
||
address: 33257 # Meter active power A
|
||
type: input
|
||
decode: int32
|
||
scale: -1
|
||
- source: modbus
|
||
{{- include "modbus" . | indent 2 }}
|
||
register:
|
||
address: 33259 # Meter active power B
|
||
type: input
|
||
decode: int32
|
||
scale: -1
|
||
- source: modbus
|
||
{{- include "modbus" . | indent 2 }}
|
||
register:
|
||
address: 33261 # Meter active power C
|
||
type: input
|
||
decode: int32
|
||
scale: -1
|
||
{{- end }}
|
||
{{- if eq .usage "pv" }}
|
||
power:
|
||
source: modbus
|
||
{{- include "modbus" . | indent 2 }}
|
||
register:
|
||
type: input
|
||
address: 33057 # Total DC output power (PV Power)
|
||
decode: uint32
|
||
energy:
|
||
source: modbus
|
||
{{- include "modbus" . | indent 2 }}
|
||
register:
|
||
address: 33029 # Total energy generation
|
||
type: input
|
||
decode: uint32
|
||
maxacpower: {{ .maxacpower }} # W
|
||
{{- end }}
|
||
{{- if eq .usage "battery" }}
|
||
power:
|
||
source: calc
|
||
mul:
|
||
- source: modbus
|
||
{{- include "modbus" . | indent 4 }}
|
||
register:
|
||
type: input
|
||
address: 33149 # Battery power
|
||
decode: uint32
|
||
- source: calc
|
||
add:
|
||
- source: modbus
|
||
{{- include "modbus" . | indent 6 }}
|
||
register:
|
||
type: input
|
||
address: 33135 # Battery current direction
|
||
decode: uint16 # 0:charge, 1:discharge
|
||
scale: 2
|
||
- source: const
|
||
value: -1
|
||
energy:
|
||
source: modbus
|
||
{{- include "modbus" . | indent 2 }}
|
||
register:
|
||
address: 33165 # Battery total discharge energy
|
||
type: input
|
||
decode: uint32
|
||
soc:
|
||
source: modbus
|
||
{{- include "modbus" . | indent 2 }}
|
||
register:
|
||
address: 33139 # Battery capacity SOC
|
||
type: input
|
||
decode: uint16
|
||
capacity: {{ .capacity }} # kWh
|
||
{{- end }}
|