evcc-io/templates/definition/meter/solis-hybrid-s.yaml
andig acca717cfc
Revert "Solis Hybrid: combine RHI and S series (#16796)" (#18464)
This reverts commit 0434e51ec8a410345b48a5eac98a6f1fb40a0396.
2025-01-28 10:20:27 +01:00

134 lines
3.1 KiB
YAML
Raw Blame History

This file contains ambiguous Unicode characters

This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

template: solis-hybrid-s
products:
- brand: Ginlong
description:
generic: Solis Hybrid Inverter (S Series)
params:
- name: usage
choice: ["grid", "pv", "battery"]
allinone: true
- name: modbus
choice: ["rs485"]
baudrate: 9600
id: 1
- name: capacity
advanced: true
- name: maxacpower
render: |
type: custom
{{- if eq .usage "grid" }}
power:
source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 33263 # Meter total active power
type: input
decode: int32
scale: -1
energy:
source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 33283 # Meter total active energy from grid
type: input
decode: uint32
scale: 0.01
currents:
- source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 33252 # Meter ac current A
type: input
decode: uint16
scale: 0.01
- source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 33254 # Meter ac current B
type: input
decode: uint16
scale: 0.01
- source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 33256 # Meter ac current C
type: input
decode: uint16
scale: 0.01
powers:
- source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 33257 # Meter active power A
type: input
decode: int32
scale: -1
- source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 33259 # Meter active power B
type: input
decode: int32
scale: -1
- source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 33261 # Meter active power C
type: input
decode: int32
scale: -1
{{- end }}
{{- if eq .usage "pv" }}
power:
source: modbus
{{- include "modbus" . | indent 2 }}
register:
type: input
address: 33057 # Total DC output power (PV Power)
decode: uint32
energy:
source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 33029 # Total energy generation
type: input
decode: uint32
maxacpower: {{ .maxacpower }} # W
{{- end }}
{{- if eq .usage "battery" }}
power:
source: calc
mul:
- source: modbus
{{- include "modbus" . | indent 4 }}
register:
type: input
address: 33149 # Battery power
decode: uint32
- source: calc
add:
- source: modbus
{{- include "modbus" . | indent 6 }}
register:
type: input
address: 33135 # Battery current direction
decode: uint16 # 0:charge, 1:discharge
scale: 2
- source: const
value: -1
energy:
source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 33165 # Battery total discharge energy
type: input
decode: uint32
soc:
source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 33139 # Battery capacity SOC
type: input
decode: uint16
capacity: {{ .capacity }} # kWh
{{- end }}