template: ocpp
|
|
products:
|
|
- description:
|
|
de: OCPP v1.6 kompatible Wallbox mit Smart Charging Profile
|
|
en: OCPP v1.6 compatible charger with smart charging profile
|
|
group: generic
|
|
requirements:
|
|
description:
|
|
de: |
|
|
Voraussetzungen:
|
|
* Löschen zuvor konfigurierter Ladeprofile (z.B. durch ein anderes Backend)
|
|
* Konfiguration des Backends der Wallbox: `ws://evcc.local:8887/`
|
|
en: |
|
|
Requirements:
|
|
* Deletion prior configured load profiles (e.g. from another backend)
|
|
* Backend configuration of the charger: `ws://evcc.local:8887/`
|
|
params:
|
|
- name: stationid
|
|
required: true
|
|
help:
|
|
en: The charger's unique station id
|
|
de: Die Stations-ID der Wallbox
|
|
example: EVB-P12354
|
|
- name: connector
|
|
default: 1
|
|
valuetype: int
|
|
advanced: true
|
|
help:
|
|
en: Connector number, usually 1 for first connector.
|
|
de: Verwendeter Ladepunkt, normalerweise 1 für den ersten Anschluss.
|
|
- name: meter
|
|
default: false
|
|
valuetype: bool
|
|
help:
|
|
en: Use of the integrated meter (if present)
|
|
de: Verwendung des integrierten Zählers (falls vorhanden)
|
|
- name: idtag
|
|
valuetype: string
|
|
advanced: true
|
|
help:
|
|
en: RFID token used for transactions (currently no authorization implemented)
|
|
de: ID des Tokens, welcher für Ladevorgänge genutzt werden soll, (aktuell nicht für Autorisierung verwendet) e.g
|
|
example: 04E6B78921BBA0
|
|
render: |
|
|
type: ocpp
|
|
stationid: {{ .stationid }}
|
|
{{- if ne .connector "1 "}}
|
|
connector: {{ .connector }}
|
|
{{- end }}
|
|
{{- if ne .idtag "" }}
|
|
idtag: {{ .idtag }}
|
|
{{- end }}
|
|
{{- if ne .meter "false" }}
|
|
meter: {{ .meter }}
|
|
{{- end }}
|