network:
|
|
# schema is the HTTP schema
|
|
# setting to `https` does not enable https, it only changes the way URLs are generated
|
|
schema: http
|
|
# host is the hostname or IP address
|
|
# if the host name contains a `.local` suffix, the name will be announced on MDNS
|
|
# docker: MDNS announcements don't work. host must be set to the docker host's name.
|
|
host: evcc.local
|
|
# port is the listening port for UI and api
|
|
# evcc will listen on all available interfaces
|
|
port: 7070
|
|
|
|
interval: 10s # control cycle interval
|
|
|
|
# sponsor token enables optional features (request at https://cloud.evcc.io)
|
|
# sponsortoken:
|
|
|
|
# telemetry enables aggregated statistics
|
|
#
|
|
# Telemetry allows collecting usage data (grid and green energy, charge power).
|
|
# Data is aggregated, no individual charging sessions are tracked. The collected,
|
|
# anonymous data can be retrieved using https://api.evcc.io.
|
|
#
|
|
# See https://github.com/evcc-io/evcc/pull/4343 or details.
|
|
#
|
|
# For time being, this is only available to sponsors, hence data is associated with
|
|
# the sponsor token's identity.
|
|
#
|
|
# telemetry: true
|
|
|
|
# log settings
|
|
log: info
|
|
levels:
|
|
site: debug
|
|
lp-1: debug
|
|
lp-2: debug
|
|
cache: error
|
|
db: error
|
|
|
|
# meter definitions
|
|
# name can be freely chosen and is used as reference when assigning meters to site and loadpoints
|
|
# for documentation see https://docs.evcc.io/docs/devices/meters
|
|
meters:
|
|
- name: grid
|
|
type: modbus
|
|
model: sdm # SDM630
|
|
uri: rs485.fritz.box:23
|
|
rtu: true # rs485 device connected using ethernet adapter
|
|
id: 2
|
|
power: Power # default value, optionally override
|
|
energy: Sum # default value, optionally override
|
|
- name: pv
|
|
type: ...
|
|
- name: battery
|
|
type: ...
|
|
- name: charge
|
|
type: ...
|
|
|
|
# charger definitions
|
|
# name can be freely chosen and is used as reference when assigning charger to vehicle
|
|
# for documentation see https://docs.evcc.io/docs/devices/chargers
|
|
chargers:
|
|
- name: wallbe
|
|
type: wallbe # Wallbe charger
|
|
uri: 192.168.0.8:502 # ModBus address
|
|
- name: keba
|
|
type: ...
|
|
|
|
# vehicle definitions
|
|
# name can be freely chosen and is used as reference when assigning vehicle to loadpoint
|
|
# for documentation see https://docs.evcc.io/docs/devices/vehicles
|
|
vehicles:
|
|
- name: car1
|
|
type: renault
|
|
title: Zoe
|
|
capacity: 60 # kWh
|
|
user: myuser # user
|
|
password: mypassword # password
|
|
vin: WREN...
|
|
onIdentify: # set defaults when vehicle is identified
|
|
mode: pv # enable PV-charging when vehicle is identified
|
|
minSoC: 20 # immediately charge to 0% regardless of mode unless "off" (disabled)
|
|
targetSoC: 90 # limit charge to 90%
|
|
|
|
# site describes the EVU connection, PV and home battery
|
|
site:
|
|
title: Home # display name for UI
|
|
meters:
|
|
grid: grid # grid meter
|
|
pvs:
|
|
- pv # list of pv inverters/ meters
|
|
battery: battery # battery meter
|
|
prioritySoC: # give home battery priority up to this soc (empty to disable)
|
|
bufferSoC: # ignore home battery discharge above soc (empty to disable)
|
|
|
|
# loadpoint describes the charger, charge meter and connected vehicle
|
|
loadpoints:
|
|
- title: Garage # display name for UI
|
|
charger: wallbe # charger
|
|
meter: charge # charge meter
|
|
mode: "off" # set default charge mode, use "off" to disable by default if charger is publicly available
|
|
# vehicle: car1 # set default vehicle (disables vehicle detection)
|
|
resetOnDisconnect: true # set defaults when vehicle disconnects
|
|
soc:
|
|
# polling defines usage of the vehicle APIs
|
|
# Modifying the default settings it NOT recommended. It MAY deplete your vehicle's battery
|
|
# or lead to vehicle manufacturer banning you from API use. USE AT YOUR OWN RISK.
|
|
poll:
|
|
# poll mode defines under which condition the vehicle API is called:
|
|
# charging: update vehicle ONLY when charging (this is the recommended default)
|
|
# connected: update vehicle when connected (not only charging), interval defines how often
|
|
# always: always update vehicle regardless of connection state, interval defines how often (only supported for single vehicle)
|
|
mode: charging
|
|
# poll interval defines how often the vehicle API may be polled if NOT charging
|
|
interval: 60m
|
|
estimate: true # set false to disable interpolating between api updates (not recommended)
|
|
phases: 3 # electrical connection (normal charger: default 3 for 3 phase, 1p3p charger: 0 for "auto" or 1/3 for fixed phases)
|
|
enable: # pv mode enable behavior
|
|
delay: 1m # threshold must be exceeded for this long
|
|
threshold: 0 # grid power threshold (in Watts, negative=export). If zero, export must exceed minimum charge power to enable
|
|
disable: # pv mode disable behavior
|
|
delay: 3m # threshold must be exceeded for this long
|
|
threshold: 0 # maximum import power (W)
|
|
guardDuration: 5m # switch charger contactor not more often than this (default 5m)
|
|
minCurrent: 6 # minimum charge current (default 6A)
|
|
maxCurrent: 16 # maximum charge current (default 16A)
|
|
|
|
# tariffs are the fixed or variable tariffs
|
|
# cheap (tibber/awattar) can be used to define a tariff rate considered cheap enough for charging
|
|
tariffs:
|
|
currency: EUR # three letter ISO-4217 currency code (default EUR)
|
|
grid:
|
|
# either static grid price
|
|
type: fixed
|
|
price: 0.294 # EUR/kWh
|
|
|
|
# # or variable via tibber
|
|
# type: tibber
|
|
# cheap: 0.2 # EUR/kWh
|
|
# token: "476c477d8a039529478ebd690d35ddd80e3308ffc49b59c65b142321aee963a4" # access token
|
|
# homeid: "cc83e83e-8cbf-4595-9bf7-c3cf192f7d9c" # optional if multiple homes associated to account
|
|
|
|
# # or variable via awattar
|
|
# type: awattar
|
|
# cheap: 0.2 # EUR/kWh
|
|
# region: de # optional, choose at for Austria
|
|
feedin:
|
|
# rate for feeding excess (pv) energy to the grid
|
|
type: fixed
|
|
price: 0.08 # EUR/kWh
|
|
|
|
# mqtt message broker
|
|
mqtt:
|
|
# broker: localhost:1883
|
|
# topic: evcc # root topic for publishing, set empty to disable
|
|
# user:
|
|
# password:
|
|
|
|
# influx database
|
|
influx:
|
|
# url: http://localhost:8086
|
|
# database: evcc
|
|
# user:
|
|
# password:
|
|
|
|
# eebus credentials
|
|
eebus:
|
|
# uri: # :4712
|
|
# interfaces: # limit eebus to specific network interfaces
|
|
# - en0
|
|
# certificate: # local signed certificate, required, can be generated via `evcc eebus-cert`
|
|
# public: # public key
|
|
# private: # private key
|
|
|
|
# push messages
|
|
messaging:
|
|
events:
|
|
start: # charge start event
|
|
title: Charge started
|
|
msg: Started charging in "${mode}" mode
|
|
stop: # charge stop event
|
|
title: Charge finished
|
|
msg: Finished charging ${chargedEnergy:%.1fk}kWh in ${chargeDuration}.
|
|
connect: # vehicle connect event
|
|
title: Car connected
|
|
msg: "Car connected at ${pvPower:%.1fk}kW PV"
|
|
disconnect: # vehicle connected event
|
|
title: Car disconnected
|
|
msg: Car disconnected after ${connectedDuration}
|
|
soc: # vehicle soc update event
|
|
title: SoC updated
|
|
msg: Battery charged to ${vehicleSoC:%.0f}%
|
|
guest: # vehicle could not be identified
|
|
title: Unknown vehicle
|
|
msg: Unknown vehicle, guest connected?
|
|
services:
|
|
# - type: pushover
|
|
# app: # app id
|
|
# recipients:
|
|
# - # list of recipient ids
|
|
# - type: telegram
|
|
# token: # bot id
|
|
# chats:
|
|
# - # list of chat ids
|
|
# - type: email
|
|
# uri: smtp://<user>:<password>@<host>:<port>/?fromAddress=<from>&toAddresses=<to>
|