template: luxtronik
|
|
products:
|
|
- brand: Buderus
|
|
description:
|
|
generic: Logamatic HMC 20
|
|
- brand: Buderus
|
|
description:
|
|
generic: Logamatic HMC 20 Z
|
|
- brand: alpha innotec
|
|
- brand: CTA All-In-One
|
|
description:
|
|
generic: Aeroplus
|
|
- brand: Elco
|
|
- brand: Nibe
|
|
description:
|
|
generic: AP-AW10
|
|
- brand: Roth
|
|
description:
|
|
generic: ThermoAura
|
|
- brand: Roth
|
|
description:
|
|
generic: ThermoTerra
|
|
- brand: Novelan
|
|
description:
|
|
generic: WPR NET
|
|
- brand: Wolf
|
|
description:
|
|
generic: BWL
|
|
- brand: Wolf
|
|
description:
|
|
generic: BWS
|
|
group: heating
|
|
requirements:
|
|
description:
|
|
de: Für Wärmepumpen mit Luxtronik 2.1 Steuerung. Nutzt modbus-tcp. Braucht mindestens Software v3.90.3. Aktivierung über SERVICE, Systemsteuerung, Konnektivität, Smart-Home-Interface.
|
|
en: For heatpumps with Luxtronik 2.1 controller. Uses modbus-tcp. Requires software v3.90.3 or later. Enable via SERVICE, Systemsteuerung, Konnektivität, Smart-Home-Interface.
|
|
# evcc: ["sponsorship"]
|
|
params:
|
|
- name: modbus
|
|
choice: ["tcpip"]
|
|
- name: timeout
|
|
default: 10s
|
|
- name: wwoffset
|
|
type: float
|
|
unit: K
|
|
description:
|
|
de: Anhebung der Warmwassertemperatur
|
|
en: Hot water temperature boost
|
|
help:
|
|
de: Erhöht evtl. den Verschleiss des Kompressors.
|
|
en: Temperature boost offset for hot water. Possibly increases wear on compressor.
|
|
default: 0.0
|
|
example: 8.5
|
|
advanced: true
|
|
- name: heatoffset
|
|
type: float
|
|
unit: K
|
|
description:
|
|
de: Anhebung der Heizwassertemperatur
|
|
en: Heating temperature boost
|
|
default: 0.0
|
|
example: 2.0
|
|
render: |
|
|
type: sgready
|
|
{{- $heatint := mulf .heatoffset 10.0 | int64 }} # scale user input (float) and cast to int for comparison operations
|
|
{{- $waterint := mulf .wwoffset 10.0 | int64 }} # scale user input (float) and cast to int for comparison operations
|
|
getmode:
|
|
source: go
|
|
script: |
|
|
res := 2 // SGReady Normal (2)
|
|
switch {
|
|
case LPC == 2: res = 1 // LPC 2 (Lux hard limit) == SGReady 1 (dimm)
|
|
case HEAT > 0 || WW > 0: res = 3 // if any boost mode set (offset(2) or setpoint(1)) --> SGReady 3 (boost)
|
|
}
|
|
res
|
|
in:
|
|
- name: LPC
|
|
type: int
|
|
config:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 6 }}
|
|
timeout: {{ .timeout }}
|
|
register:
|
|
address: 10040 # LPC mode [0=No-Limit;1=Soft-Limit;2=Hard-Limit]
|
|
type: holding
|
|
encoding: uint16
|
|
- name: HEAT
|
|
type: int
|
|
config:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 6 }}
|
|
timeout: {{ .timeout }}
|
|
register:
|
|
address: 10000 # Heiz.Mode [0=Aus;1=Setpoint;2=Offset]
|
|
type: holding
|
|
encoding: uint16
|
|
- name: WW
|
|
type: int
|
|
config:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 6 }}
|
|
timeout: {{ .timeout }}
|
|
register:
|
|
address: 10005 # WW Mode [0=Aus;1=Setpoint;2=Offset]
|
|
type: holding
|
|
encoding: uint16
|
|
setmode:
|
|
source: switch
|
|
switch:
|
|
- case: 1 # dimm (reduzierte Leistung)
|
|
set:
|
|
source: sequence
|
|
set:
|
|
- source: const
|
|
value: 2 # Lux Hard-Limit (2)
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 10 }}
|
|
timeout: {{ .timeout }}
|
|
register:
|
|
address: 10040 # LPC mode [0=No-Limit;1=Soft-Limit;2=Hard-Limit]
|
|
type: writeholding
|
|
encoding: uint16
|
|
{{ if gt $heatint 0 -}}
|
|
- source: const
|
|
value: 0 # 0 = Heiz.Mode Aus
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 10 }}
|
|
timeout: {{ .timeout }}
|
|
register:
|
|
address: 10000 # Heiz.Mode [0=Aus;1=Setpoint;2=Offset]
|
|
type: writeholding
|
|
encoding: uint16
|
|
{{- end }}
|
|
{{ if gt $waterint 0 -}}
|
|
- source: const
|
|
value: 0 # 0 = WW.Mode Aus
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 10 }}
|
|
timeout: {{ .timeout }}
|
|
register:
|
|
address: 10005 # WW Mode [0=Aus;1=Setpoint;2=Offset]
|
|
type: writeholding
|
|
encoding: uint16
|
|
{{- end }}
|
|
- case: 2 # normal
|
|
set:
|
|
source: sequence
|
|
set:
|
|
- source: const
|
|
value: 0 # Lux No-Limit (0)
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 10 }}
|
|
timeout: {{ .timeout }}
|
|
register:
|
|
address: 10040 # LPC mode [0=No-Limit;1=Soft-Limit;2=Hard-Limit]
|
|
type: writeholding
|
|
encoding: uint16
|
|
{{ if gt $heatint 0 -}}
|
|
- source: const
|
|
value: 0 # 0 = Heiz.Mode Aus
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 10 }}
|
|
timeout: {{ .timeout }}
|
|
register:
|
|
address: 10000 # Heiz.Mode [0=Aus;1=Setpoint;2=Offset]
|
|
type: writeholding
|
|
encoding: uint16
|
|
{{- end }}
|
|
{{ if gt $waterint 0 -}}
|
|
- source: const
|
|
value: 0 # 0 = WW.Mode Aus
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 10 }}
|
|
timeout: {{ .timeout }}
|
|
register:
|
|
address: 10005 # WW Mode [0=Aus;1=Setpoint;2=Offset]
|
|
type: writeholding
|
|
encoding: uint16
|
|
{{- end }}
|
|
- case: 3 # boost
|
|
set:
|
|
source: sequence
|
|
set:
|
|
- source: const
|
|
value: 0 # Lux No-Limit (0)
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 10 }}
|
|
timeout: {{ .timeout }}
|
|
register:
|
|
address: 10040 # LPC mode [0=No-Limit;1=Soft-Limit;2=Hard-Limit]
|
|
type: writeholding
|
|
encoding: uint16
|
|
{{ if gt $heatint 0 -}}
|
|
- source: const
|
|
value: 2 # 2 = Heiz.Mode Offset
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 10 }}
|
|
timeout: {{ .timeout }}
|
|
register:
|
|
address: 10000 # Heiz.Mode [0=Aus;1=Setpoint;2=Offset]
|
|
type: writeholding
|
|
encoding: uint16
|
|
- source: const
|
|
value: {{ $heatint }}
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 10 }}
|
|
timeout: {{ .timeout }}
|
|
register:
|
|
address: 10002 # Heiz. Offset [0.1 K]
|
|
type: writeholding
|
|
encoding: int16
|
|
{{- end }}
|
|
{{ if gt $waterint 0 -}}
|
|
- source: const
|
|
value: 2 # 2 = WW Mode Offset
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 10 }}
|
|
timeout: {{ .timeout }}
|
|
register:
|
|
address: 10005 # WW Mode [0=Aus;1=Setpoint;2=Offset]
|
|
type: writeholding
|
|
encoding: uint16
|
|
- source: const
|
|
value: {{ $waterint }}
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 10 }}
|
|
timeout: {{ .timeout }}
|
|
register:
|
|
address: 10007 # WW Offset [0.1 K]
|
|
type: writeholding
|
|
encoding: int16
|
|
{{- end }}
|
|
temp:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
timeout: {{ .timeout }}
|
|
register:
|
|
address: {{ if gt $waterint 0 -}} 10120 {{ else }} 10100 {{- end }} # 10100 = Temp. x10 RL-Ist, 10120 = Temp x10 WW-Ist
|
|
type: input
|
|
encoding: uint16
|
|
scale: 0.1
|
|
limittemp:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
timeout: {{ .timeout }}
|
|
register:
|
|
address: {{ if gt $waterint 0 -}} 10121 {{ else }} 10101 {{- end }} # 10101 = Temp. x10 RL-Soll, 10121 = Temp x10 WW-Soll, 10123 = Temp x10 Tdi_solltemp
|
|
type: input
|
|
encoding: int16
|
|
scale: 0.1
|
|
power:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
timeout: {{ .timeout }}
|
|
register:
|
|
address: 10301 # 10301 = kW x0.01 Power-In elektrisch
|
|
type: input
|
|
encoding: uint16
|
|
scale: 100
|
|
energy:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
timeout: {{ .timeout }}
|
|
register:
|
|
address: 10311 # 10311 = kWh x10 kumulierter Stromverbrauch
|
|
type: input
|
|
decode: uint16
|
|
scale: 0.1
|
|
{{ include "heatpumpswitch" . }}
|