template: fronius-gen24
|
|
products:
|
|
- brand: Fronius
|
|
description:
|
|
generic: Symo GEN24 Plus
|
|
guidedsetup:
|
|
enable: true
|
|
params:
|
|
- name: usage
|
|
choice: ["grid", "pv", "battery"]
|
|
- name: host
|
|
example: 192.0.2.2
|
|
required: true
|
|
- name: port
|
|
default: 502
|
|
- name: integer
|
|
description:
|
|
de: Integer Registerzugriff (nur für Netzzähler)
|
|
en: Integer register access (grid meter only)
|
|
help:
|
|
de: Einstellung Float/Integer im Wechselrichter überprüfen
|
|
en: Verify Float/Integer setting in inverter
|
|
advanced: true
|
|
valuetype: bool
|
|
render: |
|
|
{{- if eq .usage "grid" }}
|
|
type: modbus
|
|
model: sunspec
|
|
uri: {{ .host }}:{{ .port }}
|
|
id: 200
|
|
power: {{ if .integer }}203{{ else }}213{{ end }}:W # sunspec model 203/213 meter
|
|
{{- end }}
|
|
{{- if eq .usage "pv" }}
|
|
type: custom
|
|
power:
|
|
source: calc
|
|
add:
|
|
- source: modbus
|
|
model: sunspec
|
|
uri: {{ .host }}:{{ .port }}
|
|
id: 1
|
|
value: 160:1:DCW # mppt 1
|
|
- source: modbus
|
|
model: sunspec
|
|
uri: {{ .host }}:{{ .port }}
|
|
id: 1
|
|
value: 160:2:DCW # mppt 2
|
|
{{- end }}
|
|
{{- if eq .usage "battery" }}
|
|
type: custom
|
|
power:
|
|
source: calc
|
|
add:
|
|
- source: modbus
|
|
model: sunspec
|
|
uri: {{ .host }}:{{ .port }}
|
|
id: 1
|
|
value: 160:3:DCW # mppt 3 charge
|
|
scale: -1
|
|
- source: modbus
|
|
model: sunspec
|
|
uri: {{ .host }}:{{ .port }}
|
|
id: 1
|
|
value: 160:4:DCW # mppt 4 discharge
|
|
soc:
|
|
source: modbus
|
|
model: sunspec
|
|
uri: {{ .host }}:{{ .port }}
|
|
id: 1
|
|
value: ChargeState
|
|
{{- end }}
|