evcc-io/templates/definition/meter/fronius-gen24.yaml
Andreas Linde cfb174f9f5
Some checks failed
Default / Build (push) Failing after 2m0s
Default / Build UI (push) Failing after 13s
Release / Publish Docker :release (push) Has been cancelled
Release / call-build-workflow (push) Has been cancelled
Release / Publish Github & APT release (push) Has been cancelled
More template stuff (#2164)
- Configure now asks for the users knowledge level, so advanced mode can be reached without calling with `--advanced`
- Add template for solaredge inverter
- Add beta template for sungrow inverter
- Add template for MQTT based meter
- Add more template documentation
- Add check and error message for invalid config properties when using templates
- Option to specify language specific template descriptions
- Option to make params dependent on values of other params 
- Option to add sponsortoken in advanced mode
- Option to set minCurrent in advanced mode
- Remove sponsorship requirement from Daheimladen wallbox
- Multiple fixes (FritzDect meter, Kostsal Piko meter, ...)
2022-01-09 12:59:54 +01:00

46 lines
952 B
YAML

template: fronius-gen24
description:
generic: Fronius Symo GEN24 Plus
guidedsetup:
enable: true
params:
- name: usage
choice: ["grid", "pv", "battery"]
- name: host
example: 192.0.2.2
required: true
- name: port
default: 502
render: |
{{- if eq .usage "grid" }}
type: modbus
model: sunspec
uri: {{ .host }}:{{ .port }}
id: 200
power: 213:W # sunspec model 203 meter
{{- end }}
{{- if or (eq .usage "pv") (eq .usage "battery") }}
type: custom
power:
source: calc
add:
- source: modbus
model: sunspec
uri: {{ .host }}:{{ .port }}
id: 1
value: 160:3:DCW # mppt 3 charge
scale: -1
- source: modbus
model: sunspec
uri: {{ .host }}:{{ .port }}
id: 1
value: 160:4:DCW # mppt 4 discharge
{{- end }}
{{- if eq .usage "battery" }}
soc:
source: modbus
model: sunspec
uri: {{ .host }}:{{ .port }}
id: 1
value: ChargeState
{{- end }}