evcc-io/templates/definition/meter/mqtt-meter.yaml
Andreas Linde cfb174f9f5
Some checks failed
Default / Build (push) Failing after 2m0s
Default / Build UI (push) Failing after 13s
Release / Publish Docker :release (push) Has been cancelled
Release / call-build-workflow (push) Has been cancelled
Release / Publish Github & APT release (push) Has been cancelled
More template stuff (#2164)
- Configure now asks for the users knowledge level, so advanced mode can be reached without calling with `--advanced`
- Add template for solaredge inverter
- Add beta template for sungrow inverter
- Add template for MQTT based meter
- Add more template documentation
- Add check and error message for invalid config properties when using templates
- Option to specify language specific template descriptions
- Option to make params dependent on values of other params 
- Option to add sponsortoken in advanced mode
- Option to set minCurrent in advanced mode
- Remove sponsorship requirement from Daheimladen wallbox
- Multiple fixes (FritzDect meter, Kostsal Piko meter, ...)
2022-01-09 12:59:54 +01:00

105 lines
2.8 KiB
YAML

template: mqtt-meter
description:
de: MQTT Strommessgerät
en: MQTT Meter
generic: true
requirements:
mqtt: true
params:
- name: usage
choice: [ "grid", "pv", "charge", "battery" ]
- name: power
description:
de: MQTT Topic für die Leistung (W)
en: MQTT Topic for power (W)
required: true
- name: scalepower
description:
de: Skalierung der Leistungswerte
en: Scaling of the power value
default: 1
help:
de: Die Leistung wird in Watt erwartet. Falls z.b. kW geliefert wird, kann dies hier mit dem Wert 1000 angepasst werden
en: Power is expected to be provided in Watt. If it is provided in kW instead, set this value to 1000 to correct it
- name: energy
description:
de: MQTT Topic für Energiemenge (Wh)
en: MQTT Topic for energy (Wh)
- name: scaleenergy
dependencies:
- name: energy
check: notempty
description:
de: Skalierung der Energiement
en: Scaling of the energy value
default: 1
help:
de: Die Energiemenge wird in kWh erwartet. Falls z.b. Wh geliefert wird, kann dies hier mit dem Wert 0.001 angepasst werden
en: Power is expected to be provided in kWh. If it is provided in Wh instead, set this value to 0.001 to correct it
- name: soc
description:
de: MQTT Topic für den SoC der Batterie (%)
en: MQTT Topic for battery SoC (%)
dependencies:
- name: usage
check: equal
value: battery
- name: currentp1
description:
de: MQTT Topic Stromstärke (A) Phase 1
en: MQTT Topic Amperage (A) phase 1
- name: currentp2
description:
de: MQTT Topic Stromstärke (A) Phase 2
en: MQTT Topic Amperage (A) phase 2
dependencies:
- name: currentp1
check: notempty
- name: currentp3
description:
de: MQTT Topic Stromstärke (A) Phase 3
en: MQTT Topic Amperage (A) phase 3
dependencies:
- name: currentp1
check: notempty
- name: timeout
default: 30
help:
de: Akzeptiere keine Daten die älter als dieser Wert in Sekunden ist
en: Don't accept values older than this value in seconds
render: |
type: custom
power:
source: mqtt
topic: {{ .power }}
scale: {{ .scalepower }}
timeout: {{ .timeout }}
{{- if ne .energy1 "" }}
energy:
source: mqtt
topic: {{ .energy }}
scale: {{ .scaleenergy }}
timeout: {{ .timeout }}
{{- end -}}
{{- if eq .usage "battery" }}
soc:
source: mqtt
topic: {{ .soc }}
timeout: {{ .timeout }}
{{- end -}}
{{- if ne .currentp1 "" }}
currents:
- source: mqtt
topic: {{ .currentp1 }}
timeout: {{ .timeout }}
{{- if ne .currentp2 "" }}
- source: mqtt
topic: {{ .currentp2 }}
timeout: {{ .timeout }}
{{- end -}}
{{- if ne .currentp3 "" }}
- source: mqtt
topic: {{ .currentp3 }}
timeout: {{ .timeout }}
{{- end -}}