evcc-io/templates/definition/meter/victron-energy.yaml
Andreas Linde cfb174f9f5
Some checks failed
Default / Build (push) Failing after 2m0s
Default / Build UI (push) Failing after 13s
Release / Publish Docker :release (push) Has been cancelled
Release / call-build-workflow (push) Has been cancelled
Release / Publish Github & APT release (push) Has been cancelled
More template stuff (#2164)
- Configure now asks for the users knowledge level, so advanced mode can be reached without calling with `--advanced`
- Add template for solaredge inverter
- Add beta template for sungrow inverter
- Add template for MQTT based meter
- Add more template documentation
- Add check and error message for invalid config properties when using templates
- Option to specify language specific template descriptions
- Option to make params dependent on values of other params 
- Option to add sponsortoken in advanced mode
- Option to set minCurrent in advanced mode
- Remove sponsorship requirement from Daheimladen wallbox
- Multiple fixes (FritzDect meter, Kostsal Piko meter, ...)
2022-01-09 12:59:54 +01:00

69 lines
1.5 KiB
YAML

template: victron-energy
description:
generic: Victron Energy
guidedsetup:
enable: true
params:
- name: usage
choice: [ "grid", "pv", "battery" ]
- name: host
required: true
example: 192.0.2.2
- name: port
default: 502
render: |
type: custom
power:
{{- if eq .usage "grid" }}
source: calc
add:
- source: modbus
uri: {{ .host }}:{{ .port }}
id: 50 # com.victronenergy.grid
register:
address: 2600 # L1 grid power
type: input
decode: int16
- source: modbus
uri: {{ .host }}:{{ .port }}
id: 50 # com.victronenergy.grid
register:
address: 2601 # L2 grid power
type: input
decode: int16
- source: modbus
uri: {{ .host }}:{{ .port }}
id: 50 # com.victronenergy.grid
register:
address: 2602 # L3 grid power
type: input
decode: int16
{{- end }}
{{- if eq .usage "pv" }}
source: modbus
uri: {{ .host }}:{{ .port }}
id: 20 # com.victronenergy.pvinverter
register:
address: 1052 # Total AC Power
type: input
decode: int32
{{- end }}
{{- if eq .usage "battery" }}
source: modbus
uri: {{ .host }}:{{ .port }}
id: 100 # com.victronenergy.system
register:
address: 842 # active DC power
type: input
decode: int16
scale: -1
soc:
source: modbus
uri: {{ .host }}:{{ .port }}
id: 225 # com.victronenergy.battery
register:
address: 266 # SoC
type: input
decode: uint16
scale: 0.1
{{- end }}