template: fronius-argeno
|
|
products:
|
|
- brand: Fronius
|
|
description:
|
|
generic: Argeno
|
|
requirements:
|
|
description:
|
|
de: |
|
|
Modbus TCP muss am Wechselrichter aktiviert sein (Konfiguration → Kommunikation → Ethernet → Modbus TCP/UDP). Für den Netzzähler siehe Template „Fronius Smart Meter IP" — der Argeno nutzt den Smart Meter IP als eigenständiges Netzwerkgerät.
|
|
en: |
|
|
Modbus TCP must be enabled on the inverter (Configuration → Communication → Ethernet → Modbus TCP/UDP). For the grid meter see the "Fronius Smart Meter IP" template — the Argeno uses the Smart Meter IP as a standalone network device.
|
|
params:
|
|
- name: usage
|
|
choice: ["pv"]
|
|
- name: host
|
|
- name: port
|
|
default: 502
|
|
- name: maxacpower
|
|
deprecated: true # read from nameplate
|
|
render: |
|
|
type: custom
|
|
# Fronius Argeno: AC output via SunSpec inverter model 113 (float, primary)
|
|
# on unit 1; 103 (int+sf) as fallback for potential firmware variants. Unlike GEN24, PV must NOT be
|
|
# read from model 160 DC channels: the Argeno's modular power stages report
|
|
# only a fraction of plant output there (verified on-site: 160-based read
|
|
# showed 6.5 kW while actual AC output was 31.7 kW).
|
|
power:
|
|
source: sunspec
|
|
uri: {{ joinHostPort .host .port }}
|
|
id: 1
|
|
value:
|
|
- 113:W
|
|
- 103:W
|
|
energy:
|
|
source: sunspec
|
|
uri: {{ joinHostPort .host .port }}
|
|
id: 1
|
|
value:
|
|
- 113:WH
|
|
- 103:WH
|
|
scale: 0.001
|
|
{{- include "sunspec-maxacpower-tcp" . }}
|