template: solaredge-inverter
|
|
products:
|
|
- brand: SolarEdge
|
|
description:
|
|
de: Wechselrichter
|
|
en: Inverter
|
|
capabilities:
|
|
- curtail
|
|
requirements:
|
|
description:
|
|
de: Nur ein System kann und darf auf den Wechselrichter zugreifen!
|
|
en: Only one system may access the inverter!
|
|
params:
|
|
- name: usage
|
|
choice: ["grid", "pv"]
|
|
- name: modbus
|
|
choice: ["tcpip", "rs485"]
|
|
id: 1
|
|
port: 1502
|
|
- name: timeout
|
|
deprecated: true
|
|
render: |
|
|
type: custom
|
|
{{- if eq .usage "grid" }}
|
|
power:
|
|
source: sunspec
|
|
{{- include "modbus" . | indent 2 }}
|
|
subdevice: 1 # Metering device
|
|
value: 203:W # sunspec 3-phase meter power reading
|
|
scale: -1
|
|
energy:
|
|
source: sunspec
|
|
{{- include "modbus" . | indent 2 }}
|
|
subdevice: 1 # Metering device
|
|
value: 203:TotWhImp
|
|
scale: 0.001
|
|
returnenergy:
|
|
source: sunspec
|
|
{{- include "modbus" . | indent 2 }}
|
|
subdevice: 1 # Metering device
|
|
value: 203:TotWhExp
|
|
scale: 0.001
|
|
currents:
|
|
- source: sunspec
|
|
{{- include "modbus" . | indent 4 }}
|
|
subdevice: 1 # Metering device
|
|
value: 203:AphA
|
|
- source: sunspec
|
|
{{- include "modbus" . | indent 4 }}
|
|
subdevice: 1 # Metering device
|
|
value: 203:AphB
|
|
- source: sunspec
|
|
{{- include "modbus" . | indent 4 }}
|
|
subdevice: 1 # Metering device
|
|
value: 203:AphC
|
|
voltages:
|
|
- source: sunspec
|
|
{{- include "modbus" . | indent 4 }}
|
|
subdevice: 1 # Metering device
|
|
value: 203:PhVphA
|
|
- source: sunspec
|
|
{{- include "modbus" . | indent 4 }}
|
|
subdevice: 1 # Metering device
|
|
value: 203:PhVphB
|
|
- source: sunspec
|
|
{{- include "modbus" . | indent 4 }}
|
|
subdevice: 1 # Metering device
|
|
value: 203:PhVphC
|
|
powers:
|
|
- source: sunspec
|
|
{{- include "modbus" . | indent 4 }}
|
|
subdevice: 1 # Metering device
|
|
value: 203:WphA
|
|
scale: -1
|
|
- source: sunspec
|
|
{{- include "modbus" . | indent 4 }}
|
|
subdevice: 1 # Metering device
|
|
value: 203:WphB
|
|
scale: -1
|
|
- source: sunspec
|
|
{{- include "modbus" . | indent 4 }}
|
|
subdevice: 1 # Metering device
|
|
value: 203:WphC
|
|
scale: -1
|
|
{{- end }}
|
|
{{- if eq .usage "pv" }}
|
|
power:
|
|
source: sunspec
|
|
{{- include "modbus" . | indent 2 }}
|
|
value:
|
|
- 101:W
|
|
- 103:W
|
|
energy:
|
|
source: sunspec
|
|
{{- include "modbus" . | indent 2 }}
|
|
value:
|
|
- 101:WH
|
|
- 103:WH
|
|
scale: 0.001
|
|
currents:
|
|
- source: sunspec
|
|
{{- include "modbus" . | indent 4 }}
|
|
value:
|
|
- 101:AphA
|
|
- 103:AphA
|
|
- source: sunspec
|
|
{{- include "modbus" . | indent 4 }}
|
|
value:
|
|
- 101:AphB
|
|
- 103:AphB
|
|
- source: sunspec
|
|
{{- include "modbus" . | indent 4 }}
|
|
value:
|
|
- 101:AphC
|
|
- 103:AphC
|
|
curtail:
|
|
source: sequence
|
|
set:
|
|
- source: modbus
|
|
{{- include "modbus" . | indent 6 }}
|
|
register:
|
|
address: 61441 # Active Power Limit (%)
|
|
type: writesingle
|
|
encoding: uint16
|
|
- source: const
|
|
value: 1
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 8 }}
|
|
register:
|
|
address: 61696 # Commit Power Control Settings
|
|
type: writesingle
|
|
encoding: uint16
|
|
curtailed:
|
|
source: go
|
|
in:
|
|
- name: limit
|
|
type: int
|
|
config:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 8 }}
|
|
register:
|
|
address: 61441 # Active Power Limit (%)
|
|
type: holding
|
|
decode: uint16
|
|
script: |
|
|
percent := int(limit)
|
|
if percent > 100 {
|
|
percent = 100
|
|
}
|
|
percent
|
|
{{- include "sunspec-maxacpower" . }}
|
|
{{- end }}
|