template: fox-ess-avocado
|
|
products:
|
|
- brand: FoxESS
|
|
description:
|
|
generic: Avocado
|
|
capabilities: ["battery-control"]
|
|
params:
|
|
- name: usage
|
|
choice: ["grid", "pv", "battery"]
|
|
- name: modbus
|
|
choice: ["rs485", "tcpip"]
|
|
baudrate: 9600
|
|
id: 1
|
|
- name: capacity
|
|
default: 2.11 # kWh
|
|
- name: minsoc
|
|
default: 10
|
|
- name: maxsoc
|
|
default: 100
|
|
- name: maxacpower
|
|
default: 800
|
|
- name: maxchargepower
|
|
default: 1200
|
|
render: |
|
|
type: custom
|
|
{{- if eq .usage "grid" }}
|
|
power:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
register:
|
|
address: 39168 # [Meter collection] Active power
|
|
type: input
|
|
decode: int32
|
|
scale: -1 #
|
|
energy:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
register:
|
|
address: 39617 # Total power taken (grid import)
|
|
type: input
|
|
decode: uint32
|
|
scale: 0.01 # Convert to kWh (raw / 100 = kWh)
|
|
{{- end }}
|
|
{{- if eq .usage "pv" }}
|
|
power:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
register:
|
|
address: 39118 # Total PV Power
|
|
type: input
|
|
decode: int32
|
|
energy:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
register:
|
|
address: 39149 # Cumulative Generation
|
|
type: input
|
|
decode: uint32
|
|
scale: 0.01 # Convert to kWh (raw / 100 = kWh)
|
|
maxacpower: {{ .maxacpower }}
|
|
{{- end }}
|
|
{{- if eq .usage "battery" }}
|
|
power:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
register:
|
|
address: 39237 # Battery Combined Power
|
|
type: input
|
|
decode: int32
|
|
scale: -1 #
|
|
soc:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
register:
|
|
address: 39424 # Battery SOC (%)
|
|
type: input
|
|
decode: int16
|
|
limitsoc:
|
|
source: convert
|
|
convert: float2int
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 4 }}
|
|
register:
|
|
address: 46609 # Minimum SOC
|
|
type: writesingle
|
|
encoding: uint16
|
|
batterymode:
|
|
source: watchdog
|
|
timeout: 30s
|
|
reset: 1 # reset to normal mode
|
|
set:
|
|
source: switch
|
|
switch:
|
|
- case: 1 # normal - disable remote control
|
|
set:
|
|
source: sequence
|
|
set:
|
|
- source: const
|
|
value: 0 # Disabled
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 12 }}
|
|
register:
|
|
address: 46001 # Remote Control Mode
|
|
type: writesingle
|
|
encoding: uint16
|
|
- source: const
|
|
value: {{ .minsoc }}
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 12 }}
|
|
register:
|
|
address: 46609 # Minimum SOC
|
|
type: writesingle
|
|
encoding: uint16
|
|
- source: const
|
|
value: {{ .maxsoc }}
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 12 }}
|
|
register:
|
|
address: 46610 # Maximum SOC
|
|
type: writesingle
|
|
encoding: uint16
|
|
- case: 2 # hold - stop battery discharge
|
|
set:
|
|
source: sequence
|
|
set:
|
|
- source: const
|
|
value: 5 # Battery Discharge
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 12 }}
|
|
register:
|
|
address: 46001 # Remote Control Mode
|
|
type: writesingle
|
|
encoding: uint16
|
|
- source: const
|
|
value: 60 # Remote timeout 60 seconds
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 12 }}
|
|
register:
|
|
address: 46002 # Remote Timeout Set
|
|
type: writesingle
|
|
encoding: uint16
|
|
- source: const
|
|
value: 0 # W
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 12 }}
|
|
register:
|
|
address: 46003 # Remote Active Power
|
|
type: writemultiple
|
|
encoding: int32
|
|
- case: 3 # charge - force battery charge
|
|
set:
|
|
source: sequence
|
|
set:
|
|
- source: const
|
|
value: 15 # INV Charge (AC First)
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 12 }}
|
|
register:
|
|
address: 46001 # Remote Control Mode
|
|
type: writesingle
|
|
encoding: uint16
|
|
- source: const
|
|
value: 60 # Remote timeout 60 seconds
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 12 }}
|
|
register:
|
|
address: 46002 # Remote Timeout Set
|
|
type: writesingle
|
|
encoding: uint16
|
|
- source: const
|
|
value: {{ .maxchargepower }}
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 12 }}
|
|
register:
|
|
address: 46003 # Remote Active Power
|
|
type: writemultiple
|
|
encoding: int32
|
|
capacity: {{ .capacity }} # kWh
|
|
maxchargepower: {{ .maxchargepower }} # W
|
|
maxdischargepower: {{ .maxacpower }} # W
|
|
minsoc: {{ .minsoc }} # %
|
|
maxsoc: {{ .maxsoc }} # %
|
|
{{- end }}
|