template: senergy
products:
- brand: Senergy
description:
generic: SE 4/5/6KTL-S1/G2 Inverter
- brand: SolarMax
description:
generic: SP Series Inverter
params:
- name: usage
choice: ["pv"]
- name: modbus
choice: ["tcpip"]
id: 1
render: |
type: custom
{{- if eq .usage "pv" }}
power:
source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 4151 # PAC
type: holding
decode: uint32
energy:
source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 4129 # Total
type: holding
decode: uint32
{{- end }}