evcc-io/templates/definition/meter/sungrow-dongle.yaml

72 lines
1.6 KiB
YAML

template: sungrow-dongle
products:
- brand: Sungrow
description:
generic: Inverter (Wifi dongle)
guidedsetup:
enable: true
requirements:
description:
generic: beta
params:
- name: usage
choice: ["grid", "pv", "battery"]
- name: modbus
choice: ["rs485", "tcpip"]
render: |
type: custom
{{- if eq .usage "grid" }}
power:
source: modbus
{{include "modbus" . | indent 2}}
register:
type: input
address: 13009 # Export power
decode: int32s
scale: -1
{{- end }}
{{- if eq .usage "pv" }}
power:
source: modbus
{{include "modbus" . | indent 2}}
register:
type: input
address: 5016 # Total DC power
decode: uint32s
{{- end }}
{{- if eq .usage "battery" }}
power:
source: calc
mul:
- source: modbus
{{include "modbus" . | indent 4}}
register:
type: holding
address: 13022 # Battery power
decode: int16
- source: calc
add:
- source: modbus
{{include "modbus" . | indent 6}}
register:
type: holding
address: 13001 # Battery running state
decode: bool16
bitmask: 2 # Charging
scale: -1
- source: modbus
{{include "modbus" . | indent 6}}
register:
type: holding
address: 13001 # Battery running state
decode: bool16
bitmask: 4 # Discharging
soc:
source: modbus
{{include "modbus" . | indent 2}}
register:
address: 13022 # Battery level
type: input
decode: int16
scale: 0.1
{{- end }}