template: atmoce
|
|
products:
|
|
- brand: Atmoce
|
|
description:
|
|
generic: MG100 M-gateway
|
|
capabilities: ["battery-control", "curtail", "dim"]
|
|
requirements:
|
|
description:
|
|
de: |
|
|
Unterstützung für Atmoce MG100 (im Lieferumfang von MC100 und MC100-T enthalten).
|
|
Der Installateur muss Modbus TCP in der Konfiguration oder über die Atmozen-App aktivieren; verfügbar ab Firmware-Version 01.01.00.18.10.
|
|
Die Funktionen 'Netzaufladung' und 'Export von Leistung ins Netz' müssen in der Atmozen-App aktiviert sein, um das Laden/Entladen des Akkus aus dem Netz zu ermöglichen.
|
|
en: |
|
|
Support for Atmoce MG100 (included with MC100 and MC100-T).
|
|
Requires installer to enable Modbus TCP in configuration or through Atmozen app; available in firmware 01.01.00.18.10 or later.
|
|
'Grid Recharging' and 'Export Power' must be enabled in the Atmozen app to allow battery (dis)charging to/from grid.
|
|
params:
|
|
- name: usage
|
|
choice: ["grid", "pv", "battery"]
|
|
- name: modbus
|
|
choice: ["tcpip"]
|
|
id: 1
|
|
- name: maxacpower
|
|
service: modbus/read?address=60027&type=holding&encoding=uint32&scale=1&resulttype=int&{modbus}
|
|
- preset: battery-minmaxsoc
|
|
- name: minsoc
|
|
advanced: true
|
|
default: 10
|
|
- name: maxsoc
|
|
advanced: true
|
|
default: 100
|
|
- name: firmware
|
|
type: choice
|
|
choice: ["<01.01.00.28.15", ">=01.01.00.28.15"]
|
|
default: "<01.01.00.28.15"
|
|
required: true
|
|
description:
|
|
de: Firmware-Version
|
|
en: Firmware version
|
|
help:
|
|
de: |
|
|
Firmware 01.01.00.28.15 und höher ermöglichen die korrekte Hold/Holdcharge-Funktionalität sowie das Dimmen und Abschalten.
|
|
Ältere Versionen unterstützen lediglich die Hold-Funktion ohne (Ent-)Ladefunktion.
|
|
en: |
|
|
Firmware 01.01.00.28.15 and higher allows for correct hold/holdcharge functionality, dimming and curtailing.
|
|
Older versions only support hold function without (dis)charge.
|
|
- name: capacity
|
|
deprecated: true
|
|
- name: maxchargepower
|
|
deprecated: true
|
|
- name: maxdischargepower
|
|
deprecated: true
|
|
render: |
|
|
type: custom
|
|
{{- if eq .usage "grid" }}
|
|
power:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
register:
|
|
address: 60073 # Grid Active Power (kW * 1000)
|
|
type: holding
|
|
decode: int32
|
|
scale: 1
|
|
energy:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
register:
|
|
address: 60184 # Cumulative Electricity Purchase Volume (kWh * 100)
|
|
type: holding
|
|
decode: uint64
|
|
scale: 0.01
|
|
returnenergy:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
register:
|
|
address: 60178 # Cumulative Electricity Sales Volume (kWh * 100)
|
|
type: holding
|
|
decode: uint64
|
|
scale: 0.01
|
|
currents:
|
|
- source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
register:
|
|
address: 60090 # Phase A Grid Current (A * 100)
|
|
type: holding
|
|
decode: int16
|
|
block: # 60089-60094
|
|
register: 60089
|
|
count: 6
|
|
scale: 0.01
|
|
- source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
register:
|
|
address: 60092 # Phase B Grid Current (A * 100)
|
|
type: holding
|
|
decode: int16
|
|
block: # 60089-60094
|
|
register: 60089
|
|
count: 6
|
|
scale: 0.01
|
|
- source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
register:
|
|
address: 60094 # Phase C Grid Current (A * 100)
|
|
type: holding
|
|
decode: int16
|
|
block: # 60089-60094
|
|
register: 60089
|
|
count: 6
|
|
scale: 0.01
|
|
voltages:
|
|
- source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
register:
|
|
address: 60089 # Phase A Grid Voltage (V * 10)
|
|
type: holding
|
|
decode: uint16
|
|
block: # 60089-60094
|
|
register: 60089
|
|
count: 6
|
|
scale: 0.1
|
|
- source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
register:
|
|
address: 60091 # Phase B Grid Voltage (V * 10)
|
|
type: holding
|
|
decode: uint16
|
|
block: # 60089-60094
|
|
register: 60089
|
|
count: 6
|
|
scale: 0.1
|
|
- source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
register:
|
|
address: 60093 # Phase C Grid Voltage (V * 10)
|
|
type: holding
|
|
decode: uint16
|
|
block: # 60089-60094
|
|
register: 60089
|
|
count: 6
|
|
scale: 0.1
|
|
{{- end }}
|
|
{{- if eq .usage "pv" }}
|
|
power:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
register:
|
|
address: 60069 # Photovoltaic Power Output (kW * 1000)
|
|
type: holding
|
|
decode: uint32
|
|
scale: 1
|
|
energy:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
register:
|
|
address: 60160 # Cumulative Photovoltaic Power Generation (kWh * 100)
|
|
type: holding
|
|
decode: uint64
|
|
scale: 0.01
|
|
maxacpower: {{ .maxacpower }}
|
|
{{- if not ( eq .firmware "<01.01.00.28.15" ) }}
|
|
curtail:
|
|
source: switch
|
|
switch:
|
|
- case: 100 # No curtailment
|
|
set:
|
|
source: const
|
|
value: 0xFFFFFFFF # No limit
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 10 }}
|
|
register:
|
|
address: 60322 # Photovoltaic Maximum Power (kW * 1000)
|
|
type: writemultiple
|
|
encoding: uint32
|
|
default:
|
|
source: go
|
|
in:
|
|
- name: maxacpower
|
|
type: int
|
|
config:
|
|
source: const
|
|
value: {{ .maxacpower }}
|
|
script: |
|
|
powerlimit := ( maxacpower * curtail ) / 100
|
|
powerlimit
|
|
out:
|
|
- name: powerlimit
|
|
type: int
|
|
config:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 10 }}
|
|
register:
|
|
address: 60322 # Photovoltaic Maximum Power (kW * 1000)
|
|
type: writemultiple
|
|
encoding: uint32
|
|
curtailed: # the power limit is expressed as percent of nominal AC power
|
|
source: go
|
|
in:
|
|
- name: limit
|
|
type: int
|
|
config:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 8 }}
|
|
register:
|
|
address: 60322 # Photovoltaic Maximum Power (kW * 1000)
|
|
type: holding
|
|
decode: uint32
|
|
- name: maxacpower
|
|
type: int
|
|
config:
|
|
source: const
|
|
value: {{ .maxacpower }}
|
|
script: |
|
|
percent := 100
|
|
if limit != 0xFFFFFFFF && maxacpower > 0 {
|
|
// round, the watt conversion does not reproduce the written percent exactly
|
|
percent = (limit*100 + maxacpower/2) / maxacpower
|
|
}
|
|
percent
|
|
{{- end }}
|
|
{{- end }}
|
|
{{- if eq .usage "battery" }}
|
|
capacity:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
register:
|
|
address: 60031 # Energy Storage Capacity (kWh * 1000)
|
|
type: holding
|
|
decode: uint32
|
|
scale: 0.001
|
|
power:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
register:
|
|
address: 60071 # Energy Storage Charging/Discharging Power (kW * 1000)
|
|
type: holding
|
|
decode: int32
|
|
scale: 1
|
|
energy:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
register:
|
|
address: 60172 # Cumulative Energy Storage Discharging Capacity (kWh * 100)
|
|
type: holding
|
|
decode: uint64
|
|
scale: 0.01
|
|
returnenergy:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
register:
|
|
address: 60166 # Cumulative Energy Storage Charging Capacity (kWh * 100)
|
|
type: holding
|
|
decode: uint64
|
|
scale: 0.01
|
|
maxchargepower:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
register:
|
|
address: 60029 # Rated Energy Storage Power (kW * 1000)
|
|
type: holding
|
|
decode: uint32
|
|
scale: 0.75 # 75% of rated energy storage power
|
|
maxdischargepower:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
register:
|
|
address: 60029 # Rated Energy Storage Power (kW * 1000)
|
|
type: holding
|
|
decode: uint32
|
|
scale: 1
|
|
soc:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
register:
|
|
address: 60095 # Energy Storage SOC (%)
|
|
type: holding
|
|
decode: uint16
|
|
scale: 1
|
|
batterymode:
|
|
source: switch
|
|
switch:
|
|
- case: 1 # normal
|
|
set:
|
|
source: sequence
|
|
set:
|
|
- source: const
|
|
value: 2
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 14 }}
|
|
register:
|
|
address: 60310 # Energy Storage Forced Charging/Discharging (0 = Forced charging, 1 = Forced discharging, 2 = Exit forced charging/discharging, 99 = Pause)
|
|
type: writemultiple
|
|
decode: uint16
|
|
{{- if eq .firmware ">=01.01.00.28.15" }}
|
|
- source: const
|
|
value: 0xFFFFFFFF # No limit
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 14 }}
|
|
register:
|
|
address: 60318 # Energy Storage Maximum Charging Power (kW * 1000)
|
|
type: writemultiple
|
|
decode: uint32
|
|
- source: const
|
|
value: 0xFFFFFFFF # No limit
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 14 }}
|
|
register:
|
|
address: 60320 # Energy Storage Maximum Discharging Power (kW * 1000)
|
|
type: writemultiple
|
|
decode: uint32
|
|
{{- end }}
|
|
- case: 2 # hold -> No discharging
|
|
set:
|
|
source: sequence
|
|
set:
|
|
- source: const
|
|
value: {{ if eq .firmware "<01.01.00.28.15" }}99{{ else }}2{{ end }}
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 14 }}
|
|
register:
|
|
address: 60310 # Energy Storage Forced Charging/Discharging (0 = Forced charging, 1 = Forced discharging, 2 = Exit forced charging/discharging, 99 = Pause)
|
|
type: writemultiple
|
|
decode: uint16
|
|
{{- if eq .firmware ">=01.01.00.28.15" }}
|
|
- source: const
|
|
value: 0xFFFFFFFF # No limit
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 14 }}
|
|
register:
|
|
address: 60318 # Energy Storage Maximum Charging Power (kW * 1000)
|
|
type: writemultiple
|
|
decode: uint32
|
|
- source: const
|
|
value: 0 # Set discharge limit to 0W
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 14 }}
|
|
register:
|
|
address: 60320 # Energy Storage Maximum Discharging Power (kW * 1000)
|
|
type: writemultiple
|
|
decode: uint32
|
|
{{- end }}
|
|
- case: 3 # charge -> Enable grid charging with maximum target soc (will be stopped by evcc)
|
|
set:
|
|
source: sequence
|
|
set:
|
|
- source: const
|
|
value: {{ .maxsoc }}
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 14 }}
|
|
register:
|
|
address: 60312 # Energy Storage Forced Charging/Discharging Target SOC (%)
|
|
type: writemultiple
|
|
decode: uint16
|
|
- source: const
|
|
value: 0
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 14 }}
|
|
register:
|
|
address: 60311 # Energy Storage Forced Charging/Discharging Mode (0 = Target SOC, 1 = Charging/discharging duration)
|
|
type: writemultiple
|
|
decode: uint16
|
|
- source: const
|
|
value: 0
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 14 }}
|
|
register:
|
|
address: 60310 # Energy Storage Forced Charging/Discharging (0 = Forced charging, 1 = Forced discharging, 2 = Exit forced charging/discharging, 99 = Pause)
|
|
type: writemultiple
|
|
decode: uint16
|
|
{{- if eq .firmware ">=01.01.00.28.15" }}
|
|
- source: const
|
|
value: 0xFFFFFFFF # No limit
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 14 }}
|
|
register:
|
|
address: 60318 # Energy Storage Maximum Charging Power (kW * 1000)
|
|
type: writemultiple
|
|
decode: uint32
|
|
- source: const
|
|
value: 0xFFFFFFFF # No limit
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 14 }}
|
|
register:
|
|
address: 60320 # Energy Storage Maximum Discharging Power (kW * 1000)
|
|
type: writemultiple
|
|
decode: uint32
|
|
{{- end }}
|
|
- case: 4 # holdcharge -> No charging
|
|
set:
|
|
source: sequence
|
|
set:
|
|
- source: const
|
|
value: {{ if eq .firmware "<01.01.00.28.15" }}99{{ else }}2{{ end }}
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 14 }}
|
|
register:
|
|
address: 60310 # Energy Storage Forced Charging/Discharging (0 = Forced charging, 1 = Forced discharging, 2 = Exit forced charging/discharging, 99 = Pause)
|
|
type: writemultiple
|
|
decode: uint16
|
|
{{- if eq .firmware ">=01.01.00.28.15" }}
|
|
- source: const
|
|
value: 0 # Set charge limit to 0W
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 14 }}
|
|
register:
|
|
address: 60318 # Energy Storage Maximum Charging Power (kW * 1000)
|
|
type: writemultiple
|
|
decode: uint32
|
|
- source: const
|
|
value: 0xFFFFFFFF # No limit
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 14 }}
|
|
register:
|
|
address: 60320 # Energy Storage Maximum Discharging Power (kW * 1000)
|
|
type: writemultiple
|
|
decode: uint32
|
|
{{- end }}
|
|
default:
|
|
source: error
|
|
error: ErrNotAvailable
|
|
{{- if not ( eq .firmware "<01.01.00.28.15" ) }}
|
|
dim:
|
|
source: ifelse
|
|
if:
|
|
source: convert
|
|
convert: bool2int
|
|
set:
|
|
source: const
|
|
value: 0 # Set grid import limit to 0W
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 8 }}
|
|
register:
|
|
address: 60326 # Grid Maximum Import Power (kW * 1000)
|
|
type: writemultiple
|
|
encoding: uint32
|
|
else:
|
|
source: convert
|
|
convert: bool2int
|
|
set:
|
|
source: const
|
|
value: 0xFFFFFFFF # No limit
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 8 }}
|
|
register:
|
|
address: 60326 # Grid Maximum Import Power (kW * 1000)
|
|
type: writemultiple
|
|
encoding: uint32
|
|
dimmed:
|
|
source: go
|
|
in:
|
|
- name: limit
|
|
type: int
|
|
config:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 8 }}
|
|
register:
|
|
address: 60326 # Grid Maximum Import Power (kW * 1000)
|
|
type: holding
|
|
decode: uint32
|
|
script: limit == 0
|
|
{{- end }}
|
|
{{- include "battery-minmaxsoc" . }}
|
|
{{- end }}
|