evcc-io/templates/definition/meter/fox-ess-h3-smart.yaml

269 lines
7.4 KiB
YAML

template: fox-ess-h3-smart
products:
- brand: FoxESS
description:
generic: H3-Pro/Smart Series Hybrid Inverter
capabilities: ["battery-control"]
params:
- name: usage
choice: ["grid", "pv", "battery"]
- name: modbus
choice: ["rs485", "tcpip"]
id: 247
- name: maxacpower
- preset: battery-params
- name: maxchargepower
required: true
render: |
type: custom
{{- if eq .usage "grid" }}
power:
source: calc
add:
- source: modbus
{{- include "modbus" . | indent 4 }}
register:
address: 38816 # Meter Power R
type: holding
decode: int32
scale: -0.1
- source: modbus
{{- include "modbus" . | indent 4 }}
register:
address: 38818 # Meter Power S
type: holding
decode: int32
scale: -0.1
- source: modbus
{{- include "modbus" . | indent 4 }}
register:
address: 38820 # Meter Power T
type: holding
decode: int32
scale: -0.1
energy:
source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 39617 # Grid Consumption Total
type: holding
decode: uint32
scale: 0.01
{{- end }}
{{- if eq .usage "pv" }}
power:
source: calc
add:
- source: modbus
{{- include "modbus" . | indent 4 }}
register:
address: 39279 # PV1
type: holding
decode: int32
block: # 39279-39290
register: 39279
count: 12
- source: modbus
{{- include "modbus" . | indent 4 }}
register:
address: 39281 # PV2
type: holding
decode: int32
block: # 39279-39290
register: 39279
count: 12
- source: modbus
{{- include "modbus" . | indent 4 }}
register:
address: 39283 # PV3
type: holding
decode: int32
block: # 39279-39290
register: 39279
count: 12
- source: modbus
{{- include "modbus" . | indent 4 }}
register:
address: 39285 # PV4
type: holding
decode: int32
block: # 39279-39290
register: 39279
count: 12
- source: modbus
{{- include "modbus" . | indent 4 }}
register:
address: 39287 # PV5
type: holding
decode: int32
block: # 39279-39290
register: 39279
count: 12
- source: modbus
{{- include "modbus" . | indent 4 }}
register:
address: 39289 # PV6
type: holding
decode: int32
block: # 39279-39290
register: 39279
count: 12
maxacpower: {{ .maxacpower }}
{{- end }}
{{- if eq .usage "battery" }}
power:
source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 39237 # Battery Charge/Discharge
type: holding
decode: int32
soc:
source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 37612 # Soc
type: holding
decode: int16
limitsoc:
source: convert
convert: float2int
set:
source: modbus
{{- include "modbus" . | indent 4 }}
register:
address: 46611 # Minimum SoC OnGrid
type: writesingle
decode: uint16
batterymode:
source: watchdog
timeout: 30s
reset: 1 # reset to normal mode
set:
source: switch
switch:
- case: 1 # normal - disable remote control
set:
source: sequence
set:
- source: const
value: 0 # Disabled
set:
source: modbus
{{- include "modbus" . | indent 12 }}
register:
address: 46001 # Remote Control
type: writesingle
encoding: uint16
- source: const
value: 1 # Self Use
set:
source: modbus
{{- include "modbus" . | indent 12 }}
register:
address: 49203 # Work Mode
type: writesingle
encoding: uint16
- source: const
value: {{ .minsoc }}
set:
source: modbus
{{- include "modbus" . | indent 12 }}
register:
address: 46609 # Minimum SoC
type: writesingle
encoding: uint16
- source: const
value: {{ .maxsoc }}
set:
source: modbus
{{- include "modbus" . | indent 12 }}
register:
address: 46610 # Maximum SoC
type: writesingle
encoding: uint16
- case: 2 # hold - stop battery discharge
set:
source: sequence
set:
- source: const
value: 2 # Feed-in First, fallback if the remote control watchdog expires
set:
source: modbus
{{- include "modbus" . | indent 12 }}
register:
address: 49203 # Work Mode
type: writesingle
encoding: uint16
- source: const
value: 60 # Remote timeout 60 seconds
set:
source: modbus
{{- include "modbus" . | indent 12 }}
register:
address: 46002 # Remote Timeout Set
type: writesingle
encoding: uint16
- source: const
value: 1 # Enabled
set:
source: modbus
{{- include "modbus" . | indent 12 }}
register:
address: 46001 # Remote Control
type: writesingle
encoding: uint16
- source: const
value: 0 # W
set:
source: modbus
{{- include "modbus" . | indent 12 }}
register:
address: 46003 # Remote Active Power, int32 across 46003 (high word) and 46004 (low word)
type: writemultiple
encoding: int32
- case: 3 # charge - force battery charge
set:
source: sequence
set:
- source: const
value: 3 # Back-up, fallback if the remote control watchdog expires
set:
source: modbus
{{- include "modbus" . | indent 12 }}
register:
address: 49203 # Work Mode
type: writesingle
encoding: uint16
- source: const
value: 60 # Remote timeout 60 seconds
set:
source: modbus
{{- include "modbus" . | indent 12 }}
register:
address: 46002 # Remote Timeout Set
type: writesingle
encoding: uint16
- source: const
value: 1 # Enabled
set:
source: modbus
{{- include "modbus" . | indent 12 }}
register:
address: 46001 # Remote Control
type: writesingle
encoding: uint16
- source: const
value: {{ mul .maxchargepower -1 }} # negative power means charging
set:
source: modbus
{{- include "modbus" . | indent 12 }}
register:
address: 46003 # Remote Active Power, int32 across 46003 (high word) and 46004 (low word)
type: writemultiple
encoding: int32
default:
source: error
error: ErrNotAvailable
{{- include "battery-params" . }}
{{- end }}