template: solplanet-modbus
|
|
products:
|
|
- brand: Solplanet
|
|
description:
|
|
generic: Hybrid inverter (Modbus TCP)
|
|
requirements:
|
|
description:
|
|
de: |
|
|
Nur für Wechselrichter mit eigenem Modbus-TCP-Ethernet-Port (z.B. ASW-TH Serie, KACO Blueplanet Hybrid NH3, Port eth 5&6), Protokoll AISWEI "MB001_ASW GEN-Modbus" V2.1.7.
|
|
Ältere Geräte ohne diesen Port benötigen stattdessen das `solplanet-ai-dongle` Template.
|
|
Die Import-/Export-Zählerstände des Netzzählers (46443/46445) werden von dieser Firmware nicht über Modbus TCP bereitgestellt.
|
|
Bei zwei Batteriepaketen (BMS1 + BMS2) je einen Batteriezähler mit Batteriespeichernummer 1 und 2 anlegen.
|
|
en: |
|
|
Only for inverters with a dedicated Modbus TCP ethernet port (e.g. ASW-TH series, KACO Blueplanet Hybrid NH3, port eth 5&6), protocol AISWEI "MB001_ASW GEN-Modbus" V2.1.7.
|
|
Older devices without that port need the `solplanet-ai-dongle` template instead.
|
|
The grid meter import/export energy counters (46443/46445) are not exposed over Modbus TCP by this firmware.
|
|
With two battery packs (BMS1 + BMS2) add one battery meter each, using battery number 1 and 2.
|
|
capabilities: ["battery-control", "curtail"]
|
|
params:
|
|
- name: usage
|
|
choice: ["grid", "pv", "battery"]
|
|
- name: modbus
|
|
choice: ["tcpip"]
|
|
port: 502
|
|
id: 1
|
|
- name: battery
|
|
type: choice
|
|
choice: [1, 2]
|
|
required: true
|
|
usages: ["battery"]
|
|
description:
|
|
de: Batteriespeichernummer
|
|
en: Battery number
|
|
- preset: battery-params
|
|
- name: maxchargepower
|
|
required: true
|
|
render: |
|
|
type: custom
|
|
{{- if eq .usage "grid" }}
|
|
power:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
register:
|
|
address: 6433 # 46434 total system power (smart meter)
|
|
type: holding
|
|
decode: int32
|
|
{{- end }}
|
|
{{- if eq .usage "pv" }}
|
|
power:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
register:
|
|
address: 1600 # 31601 PV total power
|
|
type: input
|
|
decode: uint32
|
|
energy:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
register:
|
|
address: 1604 # 31605 PV E-Total (0.1 kWh)
|
|
type: input
|
|
decode: uint32
|
|
scale: 0.1
|
|
curtail: # allowed feed-in power as percent of nominal
|
|
source: sequence
|
|
set:
|
|
- source: modbus
|
|
{{- include "modbus" . | indent 6 }}
|
|
register:
|
|
address: 5402 # 45403 active power set (%Pn * 100)
|
|
type: writesingle
|
|
encoding: uint16
|
|
scale: 100
|
|
# active power control: disabled at 100% (unlimited), enabled while curtailed
|
|
- source: switch
|
|
switch:
|
|
- case: 100 # uncurtailed
|
|
set:
|
|
source: const
|
|
value: 0
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 14 }}
|
|
register:
|
|
address: 4000 # 44001 active power control function
|
|
type: writesingle
|
|
encoding: uint16
|
|
default:
|
|
source: const
|
|
value: 1
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 10 }}
|
|
register:
|
|
address: 4000
|
|
type: writesingle
|
|
encoding: uint16
|
|
curtailed: # the power limit only applies while active power control is enabled
|
|
source: go
|
|
in:
|
|
- name: ena
|
|
type: int
|
|
config:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 8 }}
|
|
register:
|
|
address: 4000
|
|
type: holding
|
|
decode: uint16
|
|
- name: percent
|
|
type: int
|
|
config:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 8 }}
|
|
register:
|
|
address: 5402
|
|
type: holding
|
|
decode: uint16
|
|
scale: 0.01
|
|
script: |
|
|
res := 100
|
|
if ena != 0 && percent > 0 && percent < 100 {
|
|
res = percent
|
|
}
|
|
res
|
|
{{- end }}
|
|
{{- if eq .usage "battery" }}
|
|
power:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
register:
|
|
address: {{ if eq .battery "2" }}1751{{ else }}1618{{ end }} # 31752/31619 BMS2/1 battery power
|
|
type: input
|
|
decode: int32
|
|
soc:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 2 }}
|
|
register:
|
|
address: {{ if eq .battery "2" }}1754{{ else }}1621{{ end }} # 31755/31622 BMS2/1 battery SoC
|
|
type: input
|
|
decode: uint16
|
|
batterymode:
|
|
source: switch
|
|
switch:
|
|
- case: 1 # normal
|
|
set:
|
|
source: const
|
|
value: 2 # normal
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 10 }}
|
|
register:
|
|
address: 1103 # 41104 battery working mode
|
|
type: writesingle
|
|
encoding: uint16
|
|
- case: 2 # hold
|
|
set:
|
|
source: sequence
|
|
set:
|
|
- source: const
|
|
value: 4 # custom
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 14 }}
|
|
register:
|
|
address: 1103
|
|
type: writesingle
|
|
encoding: uint16
|
|
- source: const
|
|
value: 0
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 14 }}
|
|
register:
|
|
address: 1152 # 41153 charge/discharge power, negative charges
|
|
type: writesingle
|
|
encoding: int16
|
|
- case: 3 # charge
|
|
set:
|
|
source: sequence
|
|
set:
|
|
- source: const
|
|
value: 4
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 14 }}
|
|
register:
|
|
address: 1103
|
|
type: writesingle
|
|
encoding: uint16
|
|
- source: const
|
|
value: {{ mul .maxchargepower -1 }}
|
|
set:
|
|
source: modbus
|
|
{{- include "modbus" . | indent 14 }}
|
|
register:
|
|
address: 1152
|
|
type: writesingle
|
|
encoding: int16
|
|
default:
|
|
source: error
|
|
error: ErrNotAvailable
|
|
{{- include "battery-params" . }}
|
|
{{- end }}
|