# Used API docs for SunEnergyXT 500 Series: https://github.com/SunEnergyXT/SunEnergyXT-500-Series/blob/main/API.en.md
template: sunenergyxt-500
products:
# single entry: the `model` param carries the Standard/PRO distinction
- brand: SunEnergyXT
description:
generic: SunEnergyXT 500 / 500 PRO
capabilities: ["battery-control"]
requirements:
description:
en: |
The battery's local mode must be enabled in the manufacturer's app.
Furthermore, the device's IP address must be set to a fixed, permanent IP address in the router.
An external meter (e.g., Shelly) measuring the grid connection point must be connected to the battery via the manufacturer's app.
It is required for the `grid` usage, and also for the `battery` usage, because the normal battery mode enables the device's
zero feed-in regulation, which reads this meter.
de: |
Der lokale Modus der Batterie muss in der Hersteller-App aktiviert werden.
Des Weiteren muss die IP-Adresse des Geräts im Router auf eine feste, dauerhafte IP-Adresse eingestellt werden.
Mit der Batterie muss ein externer Zähler (z. B. Shelly) verbunden sein, der den Hausanschlusspunkt misst (dieser wird über die Hersteller-App hinzugefügt).
Er wird für die Verwendung `grid` benötigt und ebenso für die Verwendung `battery`, da der normale Batteriemodus die
Nulleinspeise-Regelung des Geräts aktiviert, die diesen Zähler ausliest.
caveats:
- description:
de: |
Aktuell muss jeder Kopfspeicher einzeln in EVCC angelegt werden.
Mehrere Kopfspeicher in ein System zu verbinden, ist vom Hersteller angekündigt, jedoch softwareseitig noch nicht umgesetzt.
en: |
Currently, each head storage must be individually added in EVCC.
Connecting multiple head storages into one system has been announced by the manufacturer but is not yet implemented on the software side.
# link:
- description:
de: |
`maxacpower` und `maxdischargepower` werden aus dem gewählten `model` abgeleitet, wenn sie leer bleiben.
Ein ausdrücklich gesetzter Wert hat Vorrang und wird nicht auf das Modell-Limit begrenzt.
en: |
`maxacpower` and `maxdischargepower` are derived from the selected `model` when left empty.
An explicitly configured value takes precedence and is not clamped to the model limit.
params:
- name: usage
type: choice
choice: ["grid", "pv", "battery"]
required: true
- name: model
type: choice
choice: ["standard", "pro"]
required: true
description:
de: Modell
en: Model
help:
de: |
`standard` für die SunEnergyXT 500, `pro` für die SunEnergyXT 500 PRO.
Bestimmt die maximale AC- und Entladeleistung (800 W bzw. 2400 W).
en: |
`standard` for the SunEnergyXT 500, `pro` for the SunEnergyXT 500 PRO.
Determines the maximum AC and discharge power (800 W resp. 2400 W).
- name: host
required: true
# maxacpower/maxdischargepower: leave empty to derive the limit from `model`
- name: maxacpower
- preset: battery-capacity
- preset: battery-minmaxsoc
# head unit alone; each extension pack adds another 5 kWh
- name: capacity
default: 5
help:
de: |
Gesamtkapazität des Speichers: Kopfspeicher 5 kWh, jede Erweiterung +5 kWh.
Also 5 (nur Kopfspeicher), 10 (+1 Erweiterung) oder 15 (+2 Erweiterungen).
Die Anzahl der erkannten Akkupakete steht im Feld `ON` unter `/read`.
en: |
Total storage capacity: head unit 5 kWh, each extension pack adds 5 kWh.
So 5 (head unit only), 10 (+1 extension) or 15 (+2 extensions).
The number of detected battery packs is reported in the `ON` field of `/read`.
# grid charging is limited to -2400..0 W on both models
- name: maxchargepower
default: 2400
- name: maxdischargepower
- name: cache
advanced: true
default: 2s
- name: timeout
advanced: true
default: 10s
render: |
type: custom
{{- if eq .usage "grid" }}
power:
source: http
uri: http://{{ .host }}/read
cache: {{ .cache }}
timeout: {{ .timeout }}
jq: .state.reported.GP
scale: -1
{{- end }}
{{- if eq .usage "battery" }}
power:
source: http
uri: http://{{ .host }}/read
cache: {{ .cache }}
timeout: {{ .timeout }}
jq: .state.reported.BP
scale: -1
soc:
source: http
uri: http://{{ .host }}/read
cache: {{ .cache }}
timeout: {{ .timeout }}
jq: .state.reported.SC
batterymode:
source: switch
switch:
- case: 1 # normal
set:
source: http
method: POST
uri: http://{{ .host }}/write
headers:
- Content-Type: application/json
# GS must be reset explicitly: MM (zero feed-in regulation) and GS (manual
# setpoint) are independent, so a leftover GS would keep grid charging.
body: '{"state":{"MM":1,"GS":0}}'
- case: 2 # hold
set:
source: http
method: POST
uri: http://{{ .host }}/write
headers:
- Content-Type: application/json
body: '{"state":{"MM":0,"GS":0}}'
- case: 3 # charges
set:
source: http
method: POST
uri: http://{{ .host }}/write
headers:
- Content-Type: application/json
# GS < 0 means grid import / grid charging
body: '{"state":{"MM":0,"GS":-{{ .maxchargepower | int }}}}'
default:
source: error
error: ErrNotAvailable
{{- include "battery-capacity" . }}
{{- include "battery-minmaxsoc" . }}
maxchargepower: {{ .maxchargepower | int }} # W
maxdischargepower: {{ if gt (.maxdischargepower | int) 0 }}{{ .maxdischargepower | int }}{{ else }}{{ ternary 2400 800 (eq .model "pro") }}{{ end }} # W
{{- end }}
{{- if eq .usage "pv" }}
power:
source: http
uri: http://{{ .host }}/read
cache: {{ .cache }}
timeout: {{ .timeout }}
jq: .state.reported.PV
maxacpower: {{ if gt (.maxacpower | int) 0 }}{{ .maxacpower | int }}{{ else }}{{ ternary 2400 800 (eq .model "pro") }}{{ end }} # W
{{- end }}