package modbus
|
|
|
|
import (
|
|
"fmt"
|
|
"strings"
|
|
|
|
"github.com/andig/evcc/util"
|
|
"github.com/volkszaehler/mbmd/meters"
|
|
"github.com/volkszaehler/mbmd/meters/rs485"
|
|
"github.com/volkszaehler/mbmd/meters/sunspec"
|
|
)
|
|
|
|
// Register contains the ModBus register configuration
|
|
type Register struct {
|
|
Address, Length uint16
|
|
Type string
|
|
Decode string
|
|
}
|
|
|
|
// RegisterOperation creates a read operation from a register definition
|
|
func RegisterOperation(r Register) (rs485.Operation, error) {
|
|
op := rs485.Operation{
|
|
OpCode: r.Address,
|
|
ReadLen: r.Length,
|
|
}
|
|
|
|
switch strings.ToLower(r.Type) {
|
|
case "holding":
|
|
op.FuncCode = rs485.ReadHoldingReg
|
|
case "input":
|
|
op.FuncCode = rs485.ReadInputReg
|
|
default:
|
|
return rs485.Operation{}, fmt.Errorf("invalid register type: %s", r.Type)
|
|
}
|
|
|
|
switch strings.ToLower(r.Decode) {
|
|
case "float32", "ieee754":
|
|
op.Transform = rs485.RTUIeee754ToFloat64
|
|
case "float64":
|
|
op.Transform = rs485.RTUUint64ToFloat64
|
|
case "uint16":
|
|
op.Transform = rs485.RTUUint16ToFloat64
|
|
case "uint32":
|
|
op.Transform = rs485.RTUUint32ToFloat64
|
|
case "uint32s":
|
|
op.Transform = rs485.RTUUint32ToFloat64Swapped
|
|
case "uint64":
|
|
op.Transform = rs485.RTUUint64ToFloat64
|
|
case "int16":
|
|
op.Transform = rs485.RTUInt16ToFloat64
|
|
case "int32":
|
|
op.Transform = rs485.RTUInt32ToFloat64
|
|
case "int32s":
|
|
op.Transform = rs485.RTUInt32ToFloat64Swapped
|
|
default:
|
|
return rs485.Operation{}, fmt.Errorf("invalid register decoding: %s", r.Decode)
|
|
}
|
|
|
|
return op, nil
|
|
}
|
|
|
|
// Connection contains the ModBus connection configuration
|
|
type Connection struct {
|
|
ID uint8
|
|
URI, Device, Comset string
|
|
Baudrate int
|
|
RTU *bool // indicates RTU over TCP if true
|
|
}
|
|
|
|
var connections map[string]meters.Connection
|
|
|
|
func registeredConnection(key string, newConn meters.Connection) meters.Connection {
|
|
if connections == nil {
|
|
connections = make(map[string]meters.Connection)
|
|
}
|
|
|
|
if conn, ok := connections[key]; ok {
|
|
return conn
|
|
}
|
|
|
|
connections[key] = newConn
|
|
return newConn
|
|
}
|
|
|
|
// NewConnection creates physical modbus device from config
|
|
func NewConnection(log *util.Logger, uri, device, comset string, baudrate int, rtu bool) (conn meters.Connection) {
|
|
if device != "" {
|
|
conn = registeredConnection(device, meters.NewRTU(device, baudrate, comset))
|
|
}
|
|
|
|
if uri != "" {
|
|
if rtu {
|
|
conn = registeredConnection(uri, meters.NewRTUOverTCP(uri))
|
|
} else {
|
|
conn = registeredConnection(uri, meters.NewTCP(uri))
|
|
}
|
|
}
|
|
|
|
if conn == nil {
|
|
log.FATAL.Fatalf("config: invalid modbus configuration: need either uri or device")
|
|
}
|
|
|
|
return conn
|
|
}
|
|
|
|
// NewDevice creates physical modbus device from config
|
|
func NewDevice(log *util.Logger, model string, isRS485 bool) (device meters.Device, err error) {
|
|
if isRS485 {
|
|
device, err = rs485.NewDevice(strings.ToUpper(model))
|
|
} else {
|
|
device = sunspec.NewDevice(strings.ToUpper(model))
|
|
}
|
|
|
|
if device == nil {
|
|
log.FATAL.Fatalf("config: invalid modbus configuration: need either uri or device")
|
|
}
|
|
|
|
return device, err
|
|
}
|
|
|
|
// IsRS485 determines if model is a known MBMD rs485 device model
|
|
func IsRS485(model string) bool {
|
|
for k := range rs485.Producers {
|
|
if strings.ToUpper(model) == k {
|
|
return true
|
|
}
|
|
}
|
|
return false
|
|
}
|
|
|
|
// RS485FindDeviceOp checks is RS485 device supports operation
|
|
func RS485FindDeviceOp(device *rs485.RS485, measurement meters.Measurement) (op rs485.Operation) {
|
|
ops := device.Producer().Produce()
|
|
|
|
for _, o := range ops {
|
|
if o.IEC61850 == measurement {
|
|
op = o
|
|
break
|
|
}
|
|
}
|
|
|
|
return op
|
|
}
|