evcc-io/templates/definition/meter/e3dc.yaml
Andreas Linde d408767b2d
Configure: fix handling of PV systems (#4806)
- The configure intents to present devices that implement multiple usages in a single device or have linked templates and provide an easier step by step configuration experience e.g. by not asking for the same data for different usages over and over again
- Commit 880557594f changes this behaviour and now presents all devices that have multiple usages, e.g. meters that could be used as battery or pv meter
- This change introduces a new property `allineone` that should be used with the `usage` `param` the identify a device that implements multiple usages in the same device
- The filter to present these devices is extended by checking for this property
2022-10-13 13:57:15 +02:00

35 lines
897 B
YAML

template: e3dc
products:
- brand: E3DC
params:
- name: usage
choice: ["grid", "pv", "battery"]
allinone: true
- name: host
- name: port
default: 502
render: |
type: custom
power:
source: modbus
uri: {{ .host }}:{{ .port }}
register: # manual register configuration for E3/DC "Simple-Mode"
type: holding
decode: int32s
{{- if eq .usage "grid" }}
address: 40073 # Hausverbrauchs-Leistung in Watt
{{- end}}
{{- if eq .usage "pv" }}
address: 40067 # Photovoltaikleistung in Watt
{{- end}}
{{- if eq .usage "battery" }}
address: 40069 # Batterie-Leistung in Watt
scale: -1 # reverse direction
soc:
source: modbus
uri: {{ .host }}:{{ .port }}
register: # manual register configuration for E3/DC "Simple-Mode"
address: 40082 # Batterie-SOC in Prozent
type: holding
decode: uint16
{{- end}}