package provider
|
|
|
|
import (
|
|
"encoding/binary"
|
|
"errors"
|
|
"fmt"
|
|
"math"
|
|
"strings"
|
|
"time"
|
|
|
|
"github.com/evcc-io/evcc/util"
|
|
"github.com/evcc-io/evcc/util/modbus"
|
|
gridx "github.com/grid-x/modbus"
|
|
"github.com/volkszaehler/mbmd/meters"
|
|
"github.com/volkszaehler/mbmd/meters/rs485"
|
|
"github.com/volkszaehler/mbmd/meters/sunspec"
|
|
)
|
|
|
|
// Modbus implements modbus RTU and TCP access
|
|
type Modbus struct {
|
|
log *util.Logger
|
|
conn *modbus.Connection
|
|
device meters.Device
|
|
op modbus.Operation
|
|
scale float64
|
|
}
|
|
|
|
func init() {
|
|
registry.Add("modbus", NewModbusFromConfig)
|
|
}
|
|
|
|
// NewModbusFromConfig creates Modbus plugin
|
|
func NewModbusFromConfig(other map[string]interface{}) (IntProvider, error) {
|
|
cc := struct {
|
|
Model string
|
|
modbus.Settings `mapstructure:",squash"`
|
|
Register modbus.Register
|
|
Value string
|
|
Scale float64
|
|
Timeout time.Duration
|
|
}{
|
|
Scale: 1,
|
|
}
|
|
|
|
if err := util.DecodeOther(other, &cc); err != nil {
|
|
return nil, err
|
|
}
|
|
|
|
// assume RTU if not set and this is a known RS485 meter model
|
|
if cc.RTU == nil {
|
|
b := modbus.IsRS485(cc.Model)
|
|
cc.RTU = &b
|
|
}
|
|
|
|
format := modbus.TcpFormat
|
|
if cc.RTU != nil && *cc.RTU {
|
|
format = modbus.RtuFormat
|
|
}
|
|
|
|
conn, err := modbus.NewConnection(cc.URI, cc.Device, cc.Comset, cc.Baudrate, format, cc.ID)
|
|
if err != nil {
|
|
return nil, err
|
|
}
|
|
|
|
// set non-default timeout
|
|
if cc.Timeout > 0 {
|
|
conn.Timeout(cc.Timeout)
|
|
}
|
|
|
|
log := util.NewLogger("modbus")
|
|
conn.Logger(log.TRACE)
|
|
|
|
var device meters.Device
|
|
var op modbus.Operation
|
|
|
|
if cc.Value != "" && cc.Register.Decode != "" {
|
|
return nil, errors.New("modbus cannot have value and register both")
|
|
}
|
|
|
|
if cc.Value == "" && cc.Register.Decode == "" {
|
|
log.WARN.Println("missing modbus value or register - assuming Power")
|
|
cc.Value = "Power"
|
|
}
|
|
|
|
if cc.Model == "" && cc.Value != "" {
|
|
return nil, errors.New("need device model when value configured")
|
|
}
|
|
|
|
// no registered configured - need device
|
|
if cc.Register.Decode == "" {
|
|
device, err = modbus.NewDevice(cc.Model, cc.SubDevice)
|
|
|
|
// prepare device
|
|
if err == nil {
|
|
err = device.Initialize(conn)
|
|
|
|
// silence KOSTAL implementation errors
|
|
if errors.Is(err, meters.ErrPartiallyOpened) {
|
|
err = nil
|
|
}
|
|
}
|
|
|
|
if err != nil {
|
|
return nil, err
|
|
}
|
|
}
|
|
|
|
// model + value configured
|
|
if cc.Value != "" {
|
|
cc.Value = modbus.ReadingName(cc.Value)
|
|
if err := modbus.ParseOperation(device, cc.Value, &op); err != nil {
|
|
return nil, fmt.Errorf("invalid value %s", cc.Value)
|
|
}
|
|
}
|
|
|
|
// register configured
|
|
if cc.Register.Decode != "" {
|
|
if op.MBMD, err = modbus.RegisterOperation(cc.Register); err != nil {
|
|
return nil, err
|
|
}
|
|
}
|
|
|
|
mb := &Modbus{
|
|
log: log,
|
|
conn: conn,
|
|
device: device,
|
|
op: op,
|
|
scale: cc.Scale,
|
|
}
|
|
return mb, nil
|
|
}
|
|
|
|
func (m *Modbus) bytesGetter() ([]byte, error) {
|
|
if op := m.op.MBMD; op.FuncCode != 0 {
|
|
switch op.FuncCode {
|
|
case rs485.ReadHoldingReg:
|
|
return m.conn.ReadHoldingRegisters(op.OpCode, op.ReadLen)
|
|
case rs485.ReadInputReg:
|
|
return m.conn.ReadInputRegisters(op.OpCode, op.ReadLen)
|
|
default:
|
|
return nil, fmt.Errorf("unknown function code %d", op.FuncCode)
|
|
}
|
|
}
|
|
|
|
return nil, errors.New("expected rtu reading")
|
|
}
|
|
|
|
func (m *Modbus) floatGetter() (float64, error) {
|
|
var res meters.MeasurementResult
|
|
var err error
|
|
|
|
// if funccode is configured, execute the read directly
|
|
if op := m.op.MBMD; op.FuncCode != 0 {
|
|
var bytes []byte
|
|
if bytes, err = m.bytesGetter(); err != nil {
|
|
return 0, fmt.Errorf("read failed: %w", err)
|
|
}
|
|
|
|
return m.scale * op.Transform(bytes), nil
|
|
}
|
|
|
|
// if funccode is not configured, try find the reading on sunspec
|
|
if dev, ok := m.device.(*sunspec.SunSpec); ok {
|
|
if m.op.MBMD.IEC61850 != 0 {
|
|
// client := m.conn.ModbusClient()
|
|
res, err = dev.QueryOp(m.conn, m.op.MBMD.IEC61850)
|
|
} else {
|
|
res, err = dev.QueryPoint(
|
|
m.conn,
|
|
m.op.SunSpec.Model,
|
|
m.op.SunSpec.Block,
|
|
m.op.SunSpec.Point,
|
|
)
|
|
}
|
|
}
|
|
|
|
// silence NaN reading errors by assuming zero
|
|
if err != nil && errors.Is(err, meters.ErrNaN) {
|
|
res.Value = 0
|
|
err = nil
|
|
}
|
|
|
|
if err == nil {
|
|
if m.op.MBMD.IEC61850 != 0 {
|
|
m.log.TRACE.Printf("%s: %v", m.op.MBMD.IEC61850, res.Value)
|
|
} else {
|
|
m.log.TRACE.Printf("%d:%d:%s: %v", m.op.SunSpec.Model, m.op.SunSpec.Block, m.op.SunSpec.Point, res.Value)
|
|
}
|
|
}
|
|
|
|
return m.scale * res.Value, err
|
|
}
|
|
|
|
// FloatGetter executes configured modbus read operation and implements func() (float64, error)
|
|
func (m *Modbus) FloatGetter() func() (float64, error) {
|
|
return m.floatGetter
|
|
}
|
|
|
|
// IntGetter executes configured modbus read operation and implements IntProvider
|
|
func (m *Modbus) IntGetter() func() (int64, error) {
|
|
g := m.FloatGetter()
|
|
|
|
return func() (int64, error) {
|
|
res, err := g()
|
|
return int64(math.Round(res)), err
|
|
}
|
|
}
|
|
|
|
// StringGetter executes configured modbus read operation and implements IntProvider
|
|
func (m *Modbus) StringGetter() func() (string, error) {
|
|
return func() (string, error) {
|
|
bytes, err := m.bytesGetter()
|
|
if err != nil {
|
|
return "", err
|
|
}
|
|
|
|
return strings.TrimSpace(string(bytes)), nil
|
|
}
|
|
}
|
|
|
|
// UintFromBytes converts byte slice to bigendian uint value
|
|
func UintFromBytes(bytes []byte) (u uint64, err error) {
|
|
switch l := len(bytes); l {
|
|
case 2:
|
|
u = uint64(binary.BigEndian.Uint16(bytes))
|
|
case 4:
|
|
u = uint64(binary.BigEndian.Uint32(bytes))
|
|
case 8:
|
|
u = binary.BigEndian.Uint64(bytes)
|
|
default:
|
|
err = fmt.Errorf("unexpected length: %d", l)
|
|
}
|
|
|
|
return u, err
|
|
}
|
|
|
|
// BoolGetter executes configured modbus read operation and implements IntProvider
|
|
func (m *Modbus) BoolGetter() func() (bool, error) {
|
|
return func() (bool, error) {
|
|
bytes, err := m.bytesGetter()
|
|
if err != nil {
|
|
return false, err
|
|
}
|
|
|
|
u, err := UintFromBytes(bytes)
|
|
return u > 0, err
|
|
}
|
|
}
|
|
|
|
// IntSetter executes configured modbus write operation and implements SetIntProvider
|
|
func (m *Modbus) IntSetter(param string) func(int64) error {
|
|
return func(val int64) error {
|
|
var err error
|
|
|
|
// if funccode is configured, execute the read directly
|
|
if op := m.op.MBMD; op.FuncCode != 0 {
|
|
uval := uint16(int64(m.scale) * val)
|
|
|
|
switch op.FuncCode {
|
|
case gridx.FuncCodeWriteSingleRegister:
|
|
_, err = m.conn.WriteSingleRegister(op.OpCode, uval)
|
|
default:
|
|
err = fmt.Errorf("unknown function code %d", op.FuncCode)
|
|
}
|
|
} else {
|
|
err = errors.New("modbus plugin does not support writing to sunspec")
|
|
}
|
|
|
|
return err
|
|
}
|
|
}
|
|
|
|
// BoolSetter executes configured modbus write operation and implements SetBoolProvider
|
|
func (m *Modbus) BoolSetter(param string) func(bool) error {
|
|
set := m.IntSetter(param)
|
|
|
|
return func(val bool) error {
|
|
var ival int64
|
|
if val {
|
|
ival = 1
|
|
}
|
|
|
|
return set(ival)
|
|
}
|
|
}
|