@ -28,6 +28,14 @@ TODO
Collected 15min energy profile averaged over the last 30 days.
### Measured value blending
The solar forecast and the base load profile are anchored to the current situation
using the last completed 15min metrics slot, decaying linearly over 4 slots:
- base load: the measured home consumption replaces the first slot and decays into the profile
- solar: the scale factor measured production/forecasted production is applied to the first slot and decays towards 1
### End of forecast commercial value