Sofarsolar G3: add default energy storage mode (#17777)
This commit is contained in:
parent
cdd4c852c0
commit
9656e941d7
1 changed files with 8 additions and 1 deletions
|
|
@ -29,6 +29,13 @@ params:
|
|||
deprecated: true
|
||||
- name: capacity
|
||||
advanced: true
|
||||
- name: defaultmode
|
||||
description:
|
||||
de: Standardmodus für die aktive Batteriesteuerung. Gültige Werte sind 0 (Eigenbedarfsmodus), 1 (Nutzungszeitmodus), 2 (Zeitmodus), 4 (Peak-shaving Modus)
|
||||
en: Default mode for battery control. Valid values are 0 (self use), 1 (time of use), 2 (timing mode), 4 (peak-shaving mode)
|
||||
default: 0 # self use
|
||||
usages: ["battery"]
|
||||
advanced: true
|
||||
# battery control
|
||||
- name: minsoc
|
||||
type: int
|
||||
|
|
@ -150,7 +157,7 @@ render: |
|
|||
- case: 1 # normal
|
||||
set:
|
||||
source: const
|
||||
value: 0 # self-use
|
||||
value: {{ .defaultmode }} # set back to default energy storage mode
|
||||
set:
|
||||
source: ignore
|
||||
error: "modbus: response data size '18' does not match count '4'"
|
||||
|
|
|
|||
Loading…
Add table
Add a link
Reference in a new issue