Sofarsolar G3: add default energy storage mode (#17777)

This commit is contained in:
Carsten Schlipf 2024-12-18 11:01:36 +01:00 • committed by GitHub
parent cdd4c852c0
commit 9656e941d7
No known key found for this signature in database
GPG key ID: B5690EEEBB952194

View file

@ -29,6 +29,13 @@ params:
deprecated: true
- name: capacity
advanced: true
- name: defaultmode
description:
de: Standardmodus für die aktive Batteriesteuerung. Gültige Werte sind 0 (Eigenbedarfsmodus), 1 (Nutzungszeitmodus), 2 (Zeitmodus), 4 (Peak-shaving Modus)
en: Default mode for battery control. Valid values are 0 (self use), 1 (time of use), 2 (timing mode), 4 (peak-shaving mode)
default: 0 # self use
usages: ["battery"]
advanced: true
# battery control
- name: minsoc
type: int
@ -150,7 +157,7 @@ render: |
- case: 1 # normal
set:
source: const
value: 0 # self-use
value: {{ .defaultmode }} # set back to default energy storage mode
set:
source: ignore
error: "modbus: response data size '18' does not match count '4'"