Revert "Solis Hybrid: combine RHI and S series (#16796)" (#18464)

This reverts commit 0434e51ec8a410345b48a5eac98a6f1fb40a0396.
This commit is contained in:
andig 2025-01-28 10:20:27 +01:00 • committed by GitHub
parent 2dd029ae75
commit acca717cfc
No known key found for this signature in database
GPG key ID: B5690EEEBB952194
2 changed files with 142 additions and 21 deletions

View file

@ -0,0 +1,134 @@
template: solis-hybrid-s
products:
- brand: Ginlong
description:
generic: Solis Hybrid Inverter (S Series)
params:
- name: usage
choice: ["grid", "pv", "battery"]
allinone: true
- name: modbus
choice: ["rs485"]
baudrate: 9600
id: 1
- name: capacity
advanced: true
- name: maxacpower
render: |
type: custom
{{- if eq .usage "grid" }}
power:
source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 33263 # Meter total active power
type: input
decode: int32
scale: -1
energy:
source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 33283 # Meter total active energy from grid
type: input
decode: uint32
scale: 0.01
currents:
- source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 33252 # Meter ac current A
type: input
decode: uint16
scale: 0.01
- source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 33254 # Meter ac current B
type: input
decode: uint16
scale: 0.01
- source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 33256 # Meter ac current C
type: input
decode: uint16
scale: 0.01
powers:
- source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 33257 # Meter active power A
type: input
decode: int32
scale: -1
- source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 33259 # Meter active power B
type: input
decode: int32
scale: -1
- source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 33261 # Meter active power C
type: input
decode: int32
scale: -1
{{- end }}
{{- if eq .usage "pv" }}
power:
source: modbus
{{- include "modbus" . | indent 2 }}
register:
type: input
address: 33057 # Total DC output power (PV Power)
decode: uint32
energy:
source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 33029 # Total energy generation
type: input
decode: uint32
maxacpower: {{ .maxacpower }} # W
{{- end }}
{{- if eq .usage "battery" }}
power:
source: calc
mul:
- source: modbus
{{- include "modbus" . | indent 4 }}
register:
type: input
address: 33149 # Battery power
decode: uint32
- source: calc
add:
- source: modbus
{{- include "modbus" . | indent 6 }}
register:
type: input
address: 33135 # Battery current direction
decode: uint16 # 0:charge, 1:discharge
scale: 2
- source: const
value: -1
energy:
source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 33165 # Battery total discharge energy
type: input
decode: uint32
soc:
source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 33139 # Battery capacity SOC
type: input
decode: uint16
capacity: {{ .capacity }} # kWh
{{- end }}

View file

@ -1,9 +1,8 @@
template: solis-hybrid
covers: ["solis-hybrid-s"]
products:
- brand: Ginlong
description:
generic: Solis Hybrid Inverter (RHI and S series)
generic: Solis Hybrid Inverter (RHI series)
params:
- name: usage
choice: ["grid", "pv", "battery"]
@ -98,25 +97,13 @@ render: |
{{- end }}
{{- if eq .usage "battery" }}
power:
source: calc
mul:
- source: modbus
{{- include "modbus" . | indent 4 }}
register:
type: input
address: 33149 # Battery power
decode: int32
- source: calc
add:
- source: modbus
{{- include "modbus" . | indent 6 }}
register:
type: input
address: 33135 # Battery current direction
decode: uint16 # 0:charge, 1:discharge
scale: 2
- source: const
value: -1
source: modbus
{{- include "modbus" . | indent 2 }}
register:
type: input
address: 33149 # Battery power
decode: int32
scale: -1
energy:
source: modbus
{{- include "modbus" . | indent 2 }}