Update huawei-dongle-powersensor.yaml (#3060)
Clarify DC/AC for pv meter, add correct scale for battery meter
This commit is contained in:
parent
155a7373f5
commit
f7308513a7
1 changed files with 2 additions and 1 deletions
|
|
@ -71,7 +71,7 @@ render: |
|
|||
timeout: 10s
|
||||
connectdelay: 1s
|
||||
register:
|
||||
address: 32064 # Input power
|
||||
address: 32064 # Input power DC (if no battery in your system - for more precise readings use 32080 # Active generation power AC)
|
||||
type: holding
|
||||
decode: int32
|
||||
{{- end }}
|
||||
|
|
@ -86,6 +86,7 @@ render: |
|
|||
address: 37001
|
||||
type: holding
|
||||
decode: int32
|
||||
scale: -1
|
||||
soc:
|
||||
source: modbus
|
||||
{{include "modbus" . | indent 2}}
|
||||
|
|
|
|||
Loading…