template: solvis
|
|
products:
|
|
- brand: Solvis
|
|
description:
|
|
generic: SolvisControl 2/3
|
|
group: heating
|
|
capabilities: ["meter"]
|
|
requirements:
|
|
description:
|
|
de: |
|
|
Modbus TCP muss am SolvisControl unter „Einstellungen / Netzwerk“ aktiviert sein.
|
|
Die Ansteuerung erfolgt über die Warmwasser-Solltemperatur.
|
|
Eine Leistungsreduzierung (dim) unterstützt der Regler nicht.
|
|
en: |
|
|
Modbus TCP must be enabled at the SolvisControl under "Settings / Network".
|
|
Control is done via the hot water target temperature.
|
|
The controller does not support power reduction (dim).
|
|
params:
|
|
- name: host
|
|
- name: port
|
|
default: 502
|
|
- name: tempnormal
|
|
type: int
|
|
default: 48
|
|
description:
|
|
de: Solltemperatur Normalbetrieb
|
|
en: Target temperature normal mode
|
|
- name: tempboost
|
|
type: int
|
|
default: 60
|
|
description:
|
|
de: Solltemperatur Boost
|
|
en: Target temperature boost
|
|
- name: tempsource
|
|
required: true
|
|
type: choice
|
|
choice: ["warmwater", "buffer"]
|
|
default: warmwater
|
|
render: |
|
|
type: sgready
|
|
# The controller has no mode register, the mode is tracked by evcc.
|
|
# It could be read back from 2305:
|
|
# getmode:
|
|
# source: map
|
|
# values:
|
|
# {{ .tempnormal }}: 2
|
|
# {{ .tempboost }}: 3
|
|
# get:
|
|
# source: modbus
|
|
# uri: {{ joinHostPort .host .port }}
|
|
# id: 1
|
|
# register:
|
|
# address: 2305
|
|
# type: holding
|
|
# encoding: uint16
|
|
setmode:
|
|
source: switch
|
|
switch:
|
|
- case: 2 # normal
|
|
set:
|
|
source: const
|
|
value: {{ .tempnormal }}
|
|
set:
|
|
source: modbus
|
|
uri: {{ joinHostPort .host .port }}
|
|
id: 1
|
|
register:
|
|
address: 2305 # Warmwasser Solltemperatur
|
|
type: writesingle
|
|
encoding: uint16
|
|
- case: 3 # boost
|
|
set:
|
|
source: const
|
|
value: {{ .tempboost }}
|
|
set:
|
|
source: modbus
|
|
uri: {{ joinHostPort .host .port }}
|
|
id: 1
|
|
register:
|
|
address: 2305 # Warmwasser Solltemperatur
|
|
type: writesingle
|
|
encoding: uint16
|
|
- case: 1 # dim
|
|
set:
|
|
source: error
|
|
error: ErrNotAvailable
|
|
power:
|
|
source: modbus
|
|
uri: {{ joinHostPort .host .port }}
|
|
id: 1
|
|
register:
|
|
address: 33545 # Wärmepumpe Leistungsaufnahme elektrisch
|
|
type: holding
|
|
encoding: uint16
|
|
scale: 100 # 0.1 kW -> W
|
|
temp:
|
|
source: modbus
|
|
uri: {{ joinHostPort .host .port }}
|
|
id: 1
|
|
register:
|
|
address: {{ if eq .tempsource "warmwater" }}33025{{ else }}33024{{ end }} # 33025 Warmwasser S2, 33024 Warmwasserpuffer S1
|
|
type: input
|
|
encoding: int16
|
|
scale: 0.1
|
|
limittemp:
|
|
source: modbus
|
|
uri: {{ joinHostPort .host .port }}
|
|
id: 1
|
|
register:
|
|
address: 2305 # Warmwasser Solltemperatur
|
|
type: holding
|
|
encoding: uint16
|
|
{{ include "heatpumpswitch" . }}
|