127 lines
3 KiB
YAML
127 lines
3 KiB
YAML
template: sigenergy
|
|
products:
|
|
- brand: Sigenergy
|
|
description:
|
|
generic: Sigen Hybrid/Sigen PV Max/SigenStore EC
|
|
capabilities: ["battery-control"]
|
|
requirements:
|
|
description:
|
|
de: Der Elektriker muss die Funktion Modbus via TCP/IP in seiner Version der Sigen App aktivieren bevor diese Konfiguration funktional ist. Diese Option ist in der mySigen App für Kunden nicht verfügbar.
|
|
en: The electrician needs to enable the Modbus via TCP/IP in their service app before the setup is functional. This is not available in the customers mySigen app.
|
|
params:
|
|
- name: usage
|
|
choice: ["grid", "pv", "battery"]
|
|
allinone: true
|
|
- name: host
|
|
- name: port
|
|
default: 502
|
|
- name: id
|
|
default: 1
|
|
- name: capacity
|
|
advanced: true
|
|
- name: minsoc
|
|
type: int
|
|
advanced: true
|
|
- name: maxsoc
|
|
type: int
|
|
advanced: true
|
|
render: |
|
|
type: custom
|
|
{{- if eq .usage "grid" }}
|
|
power:
|
|
source: modbus
|
|
uri: {{ .host }}:{{ .port }}
|
|
id: 247
|
|
register:
|
|
address: 30005 # [Grid sensor] Active power
|
|
type: holding
|
|
decode: int32
|
|
energy:
|
|
source: modbus
|
|
uri: {{ .host }}:{{ .port }}
|
|
id: {{ .id }}
|
|
register:
|
|
address: 30562 # Accumulated import energy
|
|
type: holding
|
|
decode: uint64
|
|
scale: 0.01
|
|
currents:
|
|
- source: modbus
|
|
uri: {{ .host }}:{{ .port }}
|
|
id: {{ .id }}
|
|
register:
|
|
address: 31017 # Phase A current
|
|
type: holding
|
|
decode: int32
|
|
scale: 0.01
|
|
- source: modbus
|
|
uri: {{ .host }}:{{ .port }}
|
|
id: {{ .id }}
|
|
register:
|
|
address: 31019 # Phase B current
|
|
type: holding
|
|
decode: int32
|
|
scale: 0.01
|
|
- source: modbus
|
|
uri: {{ .host }}:{{ .port }}
|
|
id: {{ .id }}
|
|
register:
|
|
address: 31021 # Phase C current
|
|
type: holding
|
|
decode: int32
|
|
scale: 0.01
|
|
{{- end }}
|
|
{{- if eq .usage "pv" }}
|
|
power:
|
|
source: modbus
|
|
uri: {{ .host }}:{{ .port }}
|
|
id: 247
|
|
register:
|
|
type: holding
|
|
address: 30035 # Photovoltaic power
|
|
decode: int32
|
|
{{- end }}
|
|
{{- if eq .usage "battery" }}
|
|
power:
|
|
source: modbus
|
|
uri: {{ .host }}:{{ .port }}
|
|
id: 247
|
|
register:
|
|
type: holding
|
|
address: 30037 # Battery power
|
|
decode: int32
|
|
scale: -1
|
|
energy:
|
|
source: modbus
|
|
uri: {{ .host }}:{{ .port }}
|
|
id: {{ .id }}
|
|
register:
|
|
address: 30574 # Battery accumulated discharge energy
|
|
type: holding
|
|
decode: uint64
|
|
scale: 0.01
|
|
soc:
|
|
source: modbus
|
|
uri: {{ .host }}:{{ .port }}
|
|
id: 247
|
|
register:
|
|
address: 30014 # Energy storage system SOC
|
|
type: holding
|
|
decode: uint16
|
|
scale: 0.1
|
|
limitsoc:
|
|
source: convert
|
|
convert: float2int
|
|
set:
|
|
source: modbus
|
|
uri: {{ .host }}:{{ .port }}
|
|
id: 247
|
|
register:
|
|
address: 40048 # Discharge Cut-Off SoC
|
|
type: writeholding
|
|
decode: uint16
|
|
scale: 10
|
|
capacity: {{ .capacity }} # kWh
|
|
minsoc: {{ .minsoc }} # %
|
|
maxsoc: {{ .maxsoc }} # %
|
|
{{- end }}
|